Kelly KLS-8080N/NPS Sinusoidal BLDC/PMSM Controller User
’s Manual
V1.13
14
Figure 4:
waterproof connector
DJ7091Y-2.3-11 Pin Definition
(14) REV_SW: Reverse switch input. Orange
(6) RTN: Signal return or power supply return. Black
(12) FWD: Forward switch or High speed switch White
(11) 12V:12V Source Red
(25) 12V brake switch
. Yellowish
(22)
ECO: Low speed switch input Blue
(33)CAN-H:Greenish(Optional function)
(7) PWR: Controller power supply (input). Pink
(34)CAN-L:Brownish(Optional function)
DJ7091Y-2.3-21 Pin Definition
(15) Micro_SW: Throttle switch input. Gray
(3) Throttle: Throttle analog input, 0-5V. Dark Green
(20) RTN: Signal return. Black
(8) Meter: Copy signal of hall sensors. Dark Gray
(4) 5V: 5V supply output, <40mA. Purple
(2) Brake_AN
:
Brake variable regen or Boost function. Brown
DJ7061Y-2.3-21 Pin Definition
(21) RTN:Signal return. Black
(1) Temp: Motor temperature sensor input. Raddle
(5) 5V: 5V supply output,<40mA.Purple
(18) Hall A: Hall phase A. Yellow
【
This is Sine signal input on KLS-8080NPS
】
(17) Hall B: Hall phase B. Dark Green
【
This is Cosine signal input on KLS-8080NPS
】
(16) Hall C: Hall phase C. Dark Blue
【
There is no hall C signal input on KLS-8080NPS
】
Notes:
1. All RTN pins are internally connected.
2. Meter function is to copy either of hall sensors.
3. Switch to 12V is active. Open switch is inactive.
Caution:
•
Do not apply power until you are certain the controller wiring is correct and has been
double checked. Wiring faults will damage the controller.
•
Ensure that the B- wiring is securely and properly connected before applying power.
•
The preferred connection of the system contactor or circuit breaker is in series with the B+
line.
•
All contactors or circuit breakers in the B+ line must have precharge resistors across their
contacts. Lack of even one of these precharge resistors may severely damage the controller