22
Boost function is just full throttle position when you turn on boost switch even if the throttle is not
operated at all.
The boost function is still based on limiting of the motor current and battery current settings in
user program.
If disabled,the controller can provide brake sensor regen mode on the same pin as pin2.In
simple,boost and brake analog regen used the same pin as pin2.
Suggestion: Set according to the practical situation, factory default is Disable.So the default
function is brake variable regen mode.
(25)Foot switch:It is used for microswitch.If enabled,the controller will only accept the throttle
signal after received the valid foot switch signal.
If there is no foot switch signal,the controller will ignore the throttle signal.
Suggestion: Set according to the practical situation, factory default is Disable.
(26)Cruise Control:Value range: Enable and Disable
If enable,if you hold throttle at certain position about 3-4 seconds,the controller will get into
Cruise control.The Cruise function can not be activated in reversing direction.
Release throttle and turn the throttle again or turn on the brake switch will make the Cruise
control quit.
Suggestion:factory default is Disable.
(27)Change Direction:
If the direction is not what you expected after finish the Identification angle operation,please just
choose Change Direction item.
Please click Write button to activate Change Direction function.The motor direction will be what
you expected after the power supply is reset.
Suggestion:factory default is Disable.
4.2
Step 2
(1) Motor Poles: Motor Poles, The pair pole number*2. Range: 2~128
Suggestion: Set according to the real motor poles on the nameplate of the motor, factory default
is at 8.
(2) Speed Sensor Type: Speed Sensor Type, 2:Hal, 3:Resolver, 4:Line Hall. Range: 2~4
Different sensors type.By defualt,it is set at 2
If you have a motor with 5V,Sin/Cosin,GND speed sensors,please choose it at 4.And please
inquire the KLS-8080IPS model before ordering.
(3) Resolver Poles: Resolver Poles, The pair pole number*2. Range: 2~32
It is only used for the Resolver sensor type.
(4) Motor Temp Sensor: Motor Temp Sensor, 0
:
None,1:KTY84-130 or 150,2:KTY83-122.Range
0-2
Summary of Contents for KLS-H
Page 2: ...Kelly KLS H Brushless Motor Controller User s Manual V1 10 Rev 1 10 Jun 2017 ...
Page 3: ......
Page 11: ...8 Figure 2 KLS7245H mounting holes dimensions dimensions in millimeters ...
Page 12: ...9 Figure 3 KLS7250H mounting holes dimensions dimensions in millimeters ...
Page 13: ...10 Figure 4 KLS7275H mounting holes dimensions dimensions in millimeters ...
Page 14: ...11 Figure 5 KLS72xxx 8080H KLS96xxx 8080H mounting holes dimensions dimensions in millimeters ...