3.2.2.2 Optional wiring of KBS-L controller
The output signal of the pin is for Kelly current meter.
Figure4:
wiring of current meter pin
The 12V input signal of the pin supplies the second braking function of the controller.
Figure5:
wiring of BRK2
3.2.3 Communication Port
A RS232 port is provided to communicate with host computer for calibration and configuration.
F
igure 6: RS232 Interface on KBS controller
3.3 Installation Check List
Before operating the vehicle, complete the following checkout procedure. Use LED code as
a reference as listed in Table 1.
Caution:
•
Put the vehicle up on blocks to get the drive wheels off the ground before beginning these
tests.
•
Do not allow anyone to stand directly in front of or behind the vehicle during the checkout.
•
Make sure the PWR switch and the brake is off
•
Use well-insulated tools.