Page 14
Chapter
Chapter
Chapter
Chapter 4
4
4
4
Maintenance
Maintenance
Maintenance
Maintenance
There are no user-serviceable parts inside the controllers. Do not attempt to open the
controller. Or you will damage it. However, clearing the controller exterior periodically should be
necessary.
The controller is inherently a high power device. When working with any battery powered
vehicle, proper safety precautions should be taken. These include, but are not limited to: proper
training, wearing eye protection, avoiding loose clothing and jewelry, and using insulated
wrenches.
4.1
4.1
4.1
4.1 Cleaning
Cleaning
Cleaning
Cleaning
Although the controller requires virtually no maintenance after properly installation, the
following minor maintenance is recommended in certain applications.
•
Remove power by disconnecting the battery.
•
Discharge the capacitors in the controller by connecting a load (such as a contactor coil or a
horn) across the controller’s B+ and B- terminals.
•
Remove any dirt or corrosion from the bus bar area. The controller should be wiped with a
moist rag. Be sure it is dry before reconnecting the battery.
••••
Make sure the connections to the bus bars are tight. Use two wrenches for this task in order
to avoid stressing the bus bars; the wrenches should be well insulated.
4.2
4.2
4.2
4.2 Configuration
Configuration
Configuration
Configuration
You can configure the controller with a host computer through RS232.
•
Use a standard RS232 cable connecting the 9pin connector on face penal to a host computer.
The cable should be straight.
•
Provide 8V to 30V supply to PWR (either J2 pin1 or J1 pin14). Wire power supply ground to
any GND pin.
•
Do not connect B+, throttle and so on. The controller may display fault code, but it doesn't
affect programming or configuration.