15
1. Relay LED 1-3
2. Function relay 1-3
3. Quick fuse 10 A
4. Terminal block for voltage
5. Antenna contact
6. Code storage LED (red)
7. Power supply (yellow)
8. Function button
9. Coding button
10. Select button
3. Options: Quick fuse
NOTE: With a 10 A fuse fitted and the receiver
connected, the operating voltage from the terminal
block (12-24 V AC/CD) in the centre is supplied with
current from fuse number 1 (terminal block no. 2)
4. Terminal block
Operating voltage
MIN.
Power consumption
MAX.
Power consumption
12V DC
25 mA
100 mA
24V DC
15 mA
50 mA
24V AC
15 m A
50 mA
FUSES
Receiver RX1
SNABBSÄKRING