 - 8 -                                                         www.keller-druck.com            

Menu Navigation

Menu structure

Switch output 

I

:

High switching 

threshold (High)

Switch output 

II

:

Low switching  

threshold (Low)

Switch output 

I

:

Low switching  

threshold (Low)

Switch output 

II

:

High switching 

threshold (High)

Switch output 

I

:

Switching function (Fct.)

(Hysteresis / window,

NO/NC, OFF)

Switch output 

II

:

Switching function (Fct.)

(Hysteresis / window,

NO/NC, OFF)

Switch output 

I

:

Low switching 

threshold (Low)
Switch output 

II

:

High switching 

threshold (High)
Switch output 

II

:

Low switching  

threshold (Low)
Switch output 

I

:

Switching function (Fct.) 

(Hysteresis / window, 

NO/NC. OFF)
Switch output 

II

:

Switching function (Fct.) 

(Hysteresis / window, 

NO/NC. OFF)
Return to Normal 

Mode (END)

Change the pressure 

display unit ( 

Unit

)

bar

SELECT

Change the settings of 

the switch outputs  (

S Set

)

Programming mode

Switch output 

I

:

High switching threshold (High)

Pressure display

(normal mode)

Show the  

configuration

Change the 

configuration

SELECT

ENTER

ENTER

ENTER

SELECT

MPa
PSI
mbar
kPa

The currently selected menu item is 
indicated at the bottom of the display 
with arrows. These point to the corre-
sponding designations: 

I

II

, High, Low, Fct.

ENTER

Saves the 

selection

Summary of Contents for dV-22 PP

Page 1: ...May 2011 OPERATING MANUAL PRESSURE SWITCH PA 22 PS PROGRAMMER dV 22 PP PROGRAMMING SOFTWARE Pressure Switch Console...

Page 2: ...pply connection M12 plug 6 Converter connection connector plug 6 Pressure switch connection M12 socket 6 Display7 Navigating in the Menu Functions of the keys 7 Menu structure 8 Programming mode 9 Swi...

Page 3: ...y 0 5 seconds If a meter is connected to the analog output it must have an internal resistance of at least 30 k Though the pressure switches are already configured at the factory the configuration can...

Page 4: ...5 2 3 6 4 4 www keller druck com 1 M 12 plug Power supply connection 8 40 V DC 2 5 pole connector Connection to PC laptop with a converter K 107 K 104B 3 M 12 socket Connection of the pressure switch...

Page 5: ...on Programming with a PC Laptop If an interface cable from KELLER K 107 K 104 B is connected to the programmer programming can be carried out with a PC laptop using the Pressure Switch Con sole softwa...

Page 6: ...tly with the application and the functions of the pressure switch remain preserved Attention The switch outputs are inactive open during the programming mode Connection to PC Binder Plug The connector...

Page 7: ...d the status of the switch outputs with LED s LEDs for the indication of the status of the switch outputs Pressure measuring units Pressure value Programmer dV 22 PP 7 Menu Navigation Navigation in th...

Page 8: ...tch output II Low switching threshold Low Switch output I Switching function Fct Hysteresis window NO NC OFF Switch output II Switching function Fct Hysteresis window NO NC OFF Return to Normal Mode E...

Page 9: ...functions Fct Various functions can be configured for the switch outputs Hysteresis H When the high switching threshold is exceeded the output closes It only opens again when the value goes below the...

Page 10: ...nit bar PSI or MPa in which the program displays the pressure values can be selected Read out and programming of the pressure switch By pressing Read out the data of the pressure switch which is conne...

Page 11: ...pressure switch and the status of the switch outputs can be displayed Press Display to show these values How ever the actual pressure value can only be displayed if the pressure switch has an analog...

Page 12: ...claration is valid for products of which a drawing marked with the CE sign exists and which are produced according to this drawing This explanation has no validity without such a drawing As criteria f...