Luna 4X Operating Instructions
3
1. MAGNETIC SWITCH
Attention: the light uses a magnetic switch, so your compass reading may be off when you hold it
close (within 5cm or 2”) to the black on/off switch.
2. CHARGE OF THE BATTERY
Only use the supplied Li-Ion charger to charge the battery. For best results, the battery should be
charged at room temperature.
3. MAINTENANCE OF BATTERY
It is not recommended to discharge the battery after each dive. Complete discharge after every use
may reduce life time of battery. We recommend the following service procedures:
•
For storage remove battery from casing.
•
Discharge and recharge the battery at least once every 6 months.
•
Avoid deep discharge of the battery pack.
•
Store battery with approximately a 30-60% partial charge in a dry and cool place.
•
Charge fully before each dive.
•
The storage of a fully discharged battery may cause permanent damage to the battery.
4. BATTERY PROTECTION CIRCUIT
The integrated protection circuit protects the battery from overload, overcharge and deep discharge.
5. SAFETY LIGHT
The safety light on the rear side of the battery pack can be activated by switching the light
into the TEST mode. It is activated as well if the main light is automatically turned off due to
low battery voltage.
6. CHARGE LEVEL INDICATOR
The charge level indicator lights displays the available energy by taking into
account charge and discharge currents. Over time the battery may not be able
to hold 100% of the charge and the effect will be shown on the indicator. If the
battery is only capable of holding 80% of its charge, the indicator will only show
80% instead of the full 100% after a full charge. Note that the charge level
indicator may be slightly out of synchronization with the effective available
charge after a long period of time. A full discharge will synchronize the display.
INSTRUCTIONS