Important Safety Information
This product requires hot and cold water supply plus an
electrical connection (see Electrical section on page 11
for details). This product is not an electric shower.
Products manufactured by Kelda Showers are safe
and without risk provided they are installed, used and
maintained in good working order and in accordance
with our instructions and recommendations.
IMPORTANT! DO NOT operate the unit if the shower
head becomes damaged.
IMPORTANT! DO NOT restrict flow out of shower by
placing an obstruction in front of the shower head
nozzles.
G E N E R A L
1.
Read all of these instructions and retain them for
later use.
2.
DO NOT take risks with plumbing or electrical
equipment.
3.
Isolate electrical and water supplies before
proceeding with the installation.
4.
The shower head must be cleaned regularly
with descalant to remove scale and debris.
The air hoses must be cleaned periodically to
maintain performance and hygiene. PLEASE SEE
MAINTENANCE SECTION.
5.
This product is not suitable for mounting into steam
rooms or steam cubicles.
6.
The shower panel should not be installed in an
outdoor environment, including sheltered areas.
P L U M B I N G
1.
The plumbing installation must comply with water
regulations, building regulations or any particular
regulations as specified by a local water company
or water undertakers and should be in accordance
with BS EN 806 (Specifications for installations inside
buildings conveying water for human consumption.
Operation and maintenance).
2.
IMPORTANT! The hot and cold-water supply
pipes must be flushed to clear debris from before
connecting to water inlets on shower.
3.
DO NOT solder pipes or fittings within the panel
shower, this could result in damage to the product.
Use push fit or compression fittings.
4.
DO NOT use excessive force when making
connections to the mixer.
5.
All plumbing connections must be completed before
making the electrical connections.
6.
Water pressure - Kelda products are designed to
operate up to a maximum of 5 bar. If you wish to
operate outside of this please discuss with a Kelda
Engineer.
E L E C T R I C A L
1.
The installation must comply with BS 7671
‘Requirements for Electrical Installations’ (IEE wiring
regulations), building regulations or any particular
regulations as specified by the local electrical supply
company.
2.
In accordance with ‘The Plugs and Sockets etc.
(Safety) Regulations 1994’, this appliance is intended
to be permanently connected to the fixed wiring of
the electrical mains system.
3.
A 32A 30 mA Residual Current Breaker Operator
(RCBO) MUST be installed in all UK electric and
pumped shower circuits. This may be part of the
consumer unit or a separate unit.
4.
Each shower must be connected to a 3A switched
fused spur which is easily accessible. Switch off at
fused spur for maintenance or if not in use. This is a
safety procedure recommended with all electrical
appliances.
5.
Make sure all electrical connections are tight to
prevent overheating.
6.
As with all electrical appliances it is recommended
to have the shower and installation checked at least
every two years by a competent electrician to ensure
there is no deterioration due to age and usage.
3
Summary of Contents for 93007100
Page 22: ...Notes 22...