kelda 93007100 Installation Manual And User'S Manual Download Page 1

Deluxe Shower Panel

Important:

This product manual is the property of the customer and must be retained for maintenance and operational purposes

Installation Manual and 

User Guide

Flex Head   - White Glass TMV2 Thermostatic    

        

93007100 

Flex Head   - White Glass TMV2 Thermostatic - Eco Handset 

93008100

Fixed Head - White Glass TMV2 Thermostatic    

         

93009100

Fixed Head - White Glass TMV2 Thermostatic - Eco Handset   93010100 

Oct 2023

Part No. 24008

Summary of Contents for 93007100

Page 1: ...enance and operational purposes Installation Manual and User Guide Flex Head White Glass TMV2 Thermostatic 93007100 Flex Head White Glass TMV2 Thermostatic Eco Handset 93008100 Fixed Head White Glass...

Page 2: ...and Kelda s patented water saving technology within Includes TMV2 thermostatic temperature control and secondary ECO handset ideal for rinsing Fixed Head White Glass TMV2 Thermostatic 93009100 Surfac...

Page 3: ...and maintenance 2 IMPORTANT The hot and cold water supply pipes must be flushed to clear debris from before connecting to water inlets on shower 3 DO NOT solder pipes or fittings within the panel sho...

Page 4: ...0 Shower head Chrome Eco Handset 1 5m Handset Hose 240mm 1030mm Low voltage Electricity supply Control Hub Flow Sensor TMV2 Mixer Valve Water Pipe Air Pipe Hot Inlet Cold Inlet 238mm 83mm M5 Hex Fixin...

Page 5: ...k Rear Hot Cold water feed Rear Low voltage 24V Electrical link 100 240V Mains electricity supply via the OWA 60 24V AC Transformer supplied Hot Cold water feed Top Hot Cold Feed Entry Points Rear Hot...

Page 6: ...127mm 4 Panel Assembly x1 OWA 60 24V Power supply 300mm 1500mm HighVoltage Low Voltage 213mm 29mm Flex Head 93007100 93008100 Fixed Head 93009100 93010100 142mm 140mm Eco Handset 93008100 93010100 on...

Page 7: ...use extensions or multiple sockets The power supply cable must never be bent or dangerously compressed 2000mm 1850mm 50mm Installation should be completed to suit the user s requirements Installation...

Page 8: ...ing If the difference is too much then we recommend you to calibrate the valve to suit requirements of your installation as follows 1 Remove the screw handle adaptor and temperature control ring from...

Page 9: ...t the handle adaptor and make sure the protrusion at the bottom points to the 12 o clock position Secure the screw and handles 3 Test temperature of water using thermometer once water supply has been...

Page 10: ...ts with compression fittings provided 2 Use the two M3 Pozi head screws Flex Head or M5 Hex Head screws Fixed Head from the Head assembly and use them to mount the appropriate shower head to the Glass...

Page 11: ...knob Cover with Chrome cap to finish Adjust the glass panel and diverter valve brackets until in position before inserting the control knob trims into the glass fascia panel as shown Screw on the fro...

Page 12: ...Before fitting the temperature knob turn the brass ring clockwise until it stops full cold Repeat fixing method of temperature knob attachment using same method as the control knob Align the pointer o...

Page 13: ...with Part P U K Building Regulations and to the latest IEEE standards or the appropriate regulations in the country of installation 32A 30mA RCBO Up to 12 Showers 3A Switched Fused Spur AC 100 240V to...

Page 14: ...alised coverage of the water spray To use the eHandset wand lift to remove it from the handset holder Selecting an Outlet Adjusting the Temperature The temperature is adjusted by rotating the lower co...

Page 15: ...To change the fan speed settings press FAN button once There are 6 speed settings 1 6 3 To display current fan speed set press and hold FAN button for 2 seconds The number of LED flashes corresponds t...

Page 16: ...ale Fan Overheat Protection Fan Test Function Press and hold TMR button for more than 5 seconds to run the fan independently of full shower operation In the unlikely event of the fan overheating from...

Page 17: ...est Function p 12 If fan runs then check flow sensor is not jammed or faulty Temperature fluctuating Thermostatic control Boiler issue Check thermostatic mixer valve boiler for an issue call a special...

Page 18: ...ken not to get bleach chlorine or other strong cleaning agents onto the stainless steel if this occurs then panel must be thoroughly cleaned down with a stainless steel cleaning agent Quarterly Hygien...

Page 19: ...wdriver ensuring the fascia plate 2 and atomisation engine 3 are held until screw removed 3 Slowly lower fascia plate and atomisation engine 4 Carefully detach the rubber hose from the water chamber 4...

Page 20: ...his until hoses are clean Once hoses are clean flush hoses through with fresh water Shake out any excess water and wipe dry Once fully dry replace air supply hose by gently inserting into air outlet a...

Page 21: ...in one month from date of purchase providing that they are in good order and the packaging is unopened Note returned spares will be subject to a 15 restocking charge and authorisation must be obtained...

Page 22: ...Notes 22...

Page 23: ...ing Estate Chandler s Ford Eastleigh SO53 4DR UK Tel 44 0 2381 290640 Web www keldatechnology com DISPOSAL Do not dispose of with household waste Please recycle where facilities exist Check with your...