CHANGING THE CYLINDER:
Turn off the cylinder valve fully (clockwise) and allow the heater to fully cool before removing and
replacing the cylinder. Do not attempt to remove the regulator while the heater is still running.
PLACE OF GAS HEATING:
• This heater is designed to be placed on the floor and away from the walls. When using the
heater,always point it in the direction of the center of the room. Clear all combustible materials from the
vicinity of the heater.
• The appliance must be 0.5 meters away from the walls.
• The front of the unit must be clear of a minimum of 2 meters.
REPLACING THE GAS CYLINDER:
• Replacing the gas cylinder must be done in a non-flammable, well-ventilated room. The appliance is
stopped.
• Close the cylinder valve.
• Disconnect and remove the regulator from the cylinder.
• Replace the empty cylinder with a full gas cylinder, checking that the seal is in good condition and that
the hose is in good condition and is not bent or crushed or in contact with the hot surfaces of the unit.
• Gently open the cylinder valve and check for leaks (no leakage) with soapy water.
• In the event of leakage (bubbles) close the cylinder valve and eliminate leaks; If not call a qualified
technician.
VENTILATION:
Your gas heater consumes oxygen when in operation. For this reason, adequate ventilation must be
provided in the room where it is used. This ensures the elimination of the products of combustion and
allows a renewal of the air. Proper ventilation should greatly reduce the risk of condensation. The table
below shows you the proper ventilation so that the air is renewed properly
Number of Radiants
Continuously in use
Room size
Ventilation
Low Level
High Level
1
2
3
40 cubic meters- say 4m*4m*2.5
70 cubic meters- say 7m*4m*2.5
105 cubic meters- say 8.5m*4m*2.5
40 cm ²
70 cm ²
105cm ²
40 cm ²
70 cm ²
105cm ²
15