background image

Information requirment for the electric local space heaters

Model identifier(s): KTP2060 

Item 

Symbol  Value 

Unit 

Item 

Unit 

Heat output 

Type of heat input, for electric storage 
local space heaters only (select one) 

Nominal heat output

 

P

nom

 

2,0 

kW 

manual heat charge control, 
with integrated thermostat

 

NA 

Minimum heat output 
(indicative) 

P

min

 

kW 

manual heat charge control with 

room and/or outdoor 
temperature feedback

 

NA 

Maximum 
continuous heat 
output 

P

max,c

 

2,0

 

kW

 

electronic heat charge control 

with room and/or outdoor 
temperature feedback 

NA 

Auxiliary electricity 
consumption 

Fan assisted heat output

 

NA 

At nominal heat 
output 

el

max

 

N/A

 

kW

 

Type of heat output/room 

temperature control (select one) 

At minimum heat 
output 

el

min

 

N/A

 

kW

 

single stage heat output and no 
room temperature control

 

[NO] 

In standby mode 

el

sb

 

0,002

 

kW

 

Two or more manual stages, no 

room temperature control

 

[NO] 

with mechanic thermostat room 
temperature control

 

[NO] 

with electronic room 
temperature control

 

[YES] 

electronic room temperature 
control plus day timer

 

[NO] 

electronic room temperature 
control plus week timer

 

[NO] 

Other control options (multiple 

selections possible) 

room temperature control, with 
presence detection

 

[NO] 

room temperature control, with 
open window detection

 

[NO] 

with distance control option

 

[NO] 

with adaptive start control

 

[NO] 

with working time limitation

 

[NO] 

with black bulb sensor

 

[NO] 

Summary of Contents for 8445401003755

Page 1: ...Manual de instrucciones Instruction manual REF KTP2060 8445401003755 Calefactor Cer mico PTC Oscilante Torre Swing Black 2000W c mando 12 x 12 x 53 cm...

Page 2: ...ni os sin supervisi n Los ni os menores de tres a os deben mantenerse alejados a menos que est n bajo supervisi n continua Los ni os de entre tres y ocho a os solo deben encender y apagar el aparato...

Page 3: ...obre una superficie firme y nivelada INSTRUCCIONES DE FUNCIONAMIENTO Antes de conectar el enchufe a una toma aseg rese de que el suministro el ctrico en su rea coincida con el de la etiqueta de clasif...

Page 4: ...completamente antes de manipularlo o limpiarlo Para evitar el riesgo de incendio o electrocuci n dentro del aparato Limpie la pared exterior del aparato frot ndola suavemente con un pa o suave y h me...

Page 5: ...ctricidad auxiliar Salida de calor asistida por ventilador n a Con potencia calor fica nominal elm x n a kW Tipo de control de potencia calor fica temperatura ambiente seleccione uno Con potencia calo...

Page 6: ...ould be kept away unless continuously supervised Children aged from 3 years and less than 8 years shall only switch on off the appliance provided that it has been placed or installed in its intended n...

Page 7: ...NSTRUCTIONS Before inserting the plug into an electrical outlet make sure that the electrical supply in your area matches that on the rating label on the unit When plugged in turn on the Main power sw...

Page 8: ...unit Maintenance and cleaning Warning Never use detergent chemical damage plastic parts WARNING Let the appliance cool down completely before handling or cleaning To prevent risk of fire or electrocu...

Page 9: ...sted heat output NA At nominal heat output elmax N A kW Type of heat output room temperature control select one At minimum heat output elmin N A kW single stage heat output and no room temperature con...

Page 10: ...s Moreras 1 Naves 7 10 Pol Ind Camporrosso Sur 28350 Madrid Oficina Tel 34 911 34 50 46 Email info kovyx com Servicio Post Venta Tel 34 918 09 62 29 Email spv kovyx com Av de Andaluc a 208 28341 Valde...

Reviews: