![Keithley S46L Series Installation Manual Download Page 2](http://html1.mh-extra.com/html/keithley/s46l-series/s46l-series_installation-manual_3948073002.webp)
2
PA-1031 Rev. A / March 2011
S46L Microwave Switch System Relay Installation Guide
WARNING
Disconnect the power cord and all cables from the S46L before
removing the top cover.
To find the applicable installation procedure for your specific kit, refer to the “Installation reference” column
in
Table 1
, and then perform the referenced installation.
SPDT relay 1 through 4 installation
1.
Remove the two (2) screws holding relay spacers in the relay column containing the desired relay
installation location (see
Figure 1
).
Figure 1: SPDT 1 through 4 relay installation
2.
Replace the spacer with the relay in the desired location (refer to the inset in
Figure 1
labeled
“Terminated SPDT relay installation”).
3.
Install the two (2) screws removed in step 1 in the new relay column.
4.
Thread the red and black wires (from the relay) through the PVC tubing (PVC tubing, part number
TX-52-7, is part of S46L-350) (not shown). The PVC tubing may be cut to a length that will allow
the relay assembly to be removed without removing the top cover.
5.
Referring to
Figure 2
, solder the three (3) control wires to the terminals of the relay:
NOTE
The relay is assembled with its label facing up, and therefore, the pins shown in
the figure below are on the lower row.
•
Solder the red wire to the pin VCC.
•
Solder the black wire to the pin marked E1.
•
Solder the white wire to the pin marked E2.
Terminated
SPDT relay installation
Relay spacer screws
(2 per relay column)
Terminated
SPDT relay
1
2
3