![Keithley 4299-11 Assembly And Mounting Instructions Download Page 3](http://html1.mh-extra.com/html/keithley/4299-11/4299-11_assembly-and-mounting-instructions_3976854003.webp)
Model 4299-11 Universal Fixed Rack-Mount Kit
071314200 / June 2013
3
#
Description
Part number
Quantity
14
6-32 x 5/8" Phillips pan head screw
6-32x5/8PPHSEM
2
15
10-32 Keps
®
washer nut
10-32KEPNUT
5
16
8-32 x 3/8" Phillips pan head screw
8-32X3/8PPH
2
17
M4 x 12 mm Phillips pan head screw
M4X12PPH
2
18
M4 x 12 mm Phillips flat head screw
M4X12MMPFH
2
Installation
To install a single Graphical Display instrument and an adjacent 2U instrument using the Model 4299-11 Fixed
Rack-Mount Kit:
1. Review the
installation precautions
(on page 3).
2. Select a location in the rack.
3. Take steps to make it easier to manipulate and install the Graphical Display instrument:
•
Clear as much space as possible around the selected rack location
•
If practical, remove the cabinet sides from the rack
4. Perform the installation procedure beginning with
Step 1: Prepare the rack
(on page 4).
Installation precautions
Observe the following safety precautions while installing instruments.
Turn off instrument power and unplug all cables before installing an instrument in a rack.
Failure to remove power before installation may cause personal injury or death from electrical
shock.
Heat sources should be mounted away from the instrument, its cabling, and its accessories, with
sufficient space provided between the instrument and heat source for airflow and cooling.
To prevent damaging heat build-up and ensure specified performance, make sure there is adequate
ventilation and air flow around the instrument to ensure proper cooling. Do not cover the ventilation
holes on the top, sides, or bottom of the instrument.