When installing equipment where access to the main power cord is restricted, such as rack mounting, a separate main input power 
disconnect device must be provided in close proximity to the equipment and within easy reach of the operator.

For maximum safety, do not touch the product, test cables, or any other instruments while power is applied to the circuit under test. 
ALWAYS remove power from the entire test system and discharge any capacitors before: connecting or disconnecting cables or jumpers, 
installing or removing switching cards, or making internal changes, such as installing or removing jumpers.

Do not touch any object that could provide a current path to the common side of the circuit under test or power line (earth) ground. Always 
make measurements with dry hands while standing on a dry, insulated surface capable of withstanding the voltage being measured.

The instrument and accessories must be used in accordance with its specifications and operating instructions, or the safety of the 
equipment may be impaired.

Do not exceed the maximum signal levels of the instruments and accessories, as defined in the specifications and operating information, 
and as shown on the instrument or test fixture panels, or switching card.

When fuses are used in a product, replace with the same type and rating for continued protection against fire hazard.

Chassis connections must only be used as shield connections for measuring circuits, NOT as safety earth ground connections.

If you are using a test fixture, keep the lid closed while power is applied to the device under test. Safe operation requires the use of a lid 
interlock.

If a 

 screw is present, connect it to safety earth ground using the wire recommended in the user documentation.

The 

 symbol on an instrument indicates that the user should refer to the operating instructions located in the user documentation.

The 

symbol on an instrument shows that it can source or measure 1000V or more, including the combined effect of normal and 

common mode voltages. Use standard safety precautions to avoid personal contact with these voltages.

The 

 symbol on an instrument shows that the surface may be hot. Avoid personal contact to prevent burns.

The 

symbol indicates a connection terminal to the equipment frame.

If this 

 symbol is on a product, it indicates that mercury is present in the display lamp. Please note that the lamp must be properly 

disposed of according to federal, state, and local laws.

The 

WARNING

 heading in the user documentation explains dangers that might result in personal injury or death. Always read the 

associated information very carefully before performing the indicated procedure.

The 

CAUTION

 heading in the user documentation explains hazards that could damage the instrument. Such damage may invalidate the 

warranty.

Instrumentation and accessories shall not be connected to humans.

Before performing any maintenance, disconnect the line cord and all test cables.

To maintain protection from electric shock and fire, replacement components in mains circuits - including the power transformer, test leads, 
and input jacks - must be purchased from Keithley Instruments. Standard fuses with applicable national safety approvals may be used if 
the rating and type are the same. Other components that are not safety-related may be purchased from other suppliers as long as they 
are equivalent to the original component (note that selected parts should be purchased only through Keithley Instruments to maintain 
accuracy and functionality of the product). If you are unsure about the applicability of a replacement component, call a Keithley Instruments 
office for information.

To clean an instrument, use a damp cloth or mild, water-based cleaner. Clean the exterior of the instrument only. Do not apply cleaner 
directly to the instrument or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with no case or chassis 
(e.g., a data acquisition board for installation into a computer) should never require cleaning if handled according to instructions. If the 
board becomes contaminated and operation is affected, the board should be returned to the factory for proper cleaning/servicing.

!

Summary of Contents for 2602A

Page 1: ...www keithley com Series 2600A System SourceMeter Quick Start Guide 2600AS 903 01 Rev A September 2008 2600AS 903 01 A July 2008 qxp 10 6 08 1 20 PM Page 1...

Page 2: ......

Page 3: ...duct returned transportation prepaid Repaired or replaced products are warranted for the balance of the original warranty period or at least 90 days LIMITATION OF WARRANTY This warranty does not apply...

Page 4: ......

Page 5: ...e with electrical signals that are rated Measurement Category I and Measurement Category II as described in the International Electrotechnical Commission IEC Standard IEC 60664 Most measurement contro...

Page 6: ...d common mode voltages Use standard safety precautions to avoid personal contact with these voltages The symbol on an instrument shows that the surface may be hot Avoid personal contact to prevent bur...

Page 7: ...connections local sensing non floating 1 CHANNEL A and CHANNEL B 1 CHANNEL A and CHANNEL B Triax connectors 2 DIGITAL I O 2 DIGITAL I O 3 IEEE 488 3 IEEE 488 4 Cooling exhaust vent 4 Cooling exhaust v...

Page 8: ...A two wire connections local sensing Four wire Connections Model 2636A four wire connections remote sensing Model 2602A 2612A four wire connections remote sensing DUT LO CHANNEL A LO G LO HI G G G HI...

Page 9: ...00 Reference Manual section 10 for more information Step 6 Make measurements 1 Observe the readings on the display Press TRIG if necessary to trigger the unit to begin taking readings For the single c...

Page 10: ...irst Entering an incorrect IP address can prevent your PC from connecting to your corporate network 1 Open the Internet Protocol Properties dialog box In Windows 2000 a Click the Start button and open...

Page 11: ...rom within the LAN MENU a Select CONFIG IP ADDRESS b Refer to the recorded computer s IP address You will use a portion of the computer s address as a base for the instrument s unique ID Only the last...

Page 12: ...ress box EXAMPLEIf the instrument s IP address is 192 168 0 3 enter 192 168 0 3 in the browser s address box NOTE For computers do not enter any leading or trailing zeros 3 Press ENTER on the PC keybo...

Page 13: ...ur 2600A Quick start menu of TSP Express includes pre configured tests for common SMU functionality such as sweeps pulse and sequential source measure see help content on the right column for detail d...

Page 14: ...Meter Instruments Quick Start Guide 3 Assign the SMUs smua for voltage step on Gate and smub for voltage sweep on Drain 4 Set Step and Sweep Parameters 5 Click Run Step 4 View the data Data can be vie...

Page 15: ......

Page 16: ...of Keithley Instruments Inc All other trademarks and trade names are the property of their respective companies A G R E A T E R M E A S U R E O F C O N F I D E N C E Keithley Instruments Inc Corporate...

Reviews: