background image

www.keithley.com

A   G R E A T E R   M E A S U R E   O F   C O N F I D E N C E

Series 2600A System SourceMeter

®

Quick Start Guide

2600AS-903-01 Rev. A / September 2008

www.keithley.com

A   G R E A T E R   M E A S U R E   O F   C O N F I D E N C E

Series 2600A System SourceMeter

®

Quick Start Guide

2600AS-903-01 Rev. A / September 2008

2600AS-903-01 (A - July 2008).qxp  10/6/08  1:20 PM  Page 1

Summary of Contents for 2602A

Page 1: ...www keithley com Series 2600A System SourceMeter Quick Start Guide 2600AS 903 01 Rev A September 2008 2600AS 903 01 A July 2008 qxp 10 6 08 1 20 PM Page 1...

Page 2: ......

Page 3: ...duct returned transportation prepaid Repaired or replaced products are warranted for the balance of the original warranty period or at least 90 days LIMITATION OF WARRANTY This warranty does not apply...

Page 4: ......

Page 5: ...e with electrical signals that are rated Measurement Category I and Measurement Category II as described in the International Electrotechnical Commission IEC Standard IEC 60664 Most measurement contro...

Page 6: ...d common mode voltages Use standard safety precautions to avoid personal contact with these voltages The symbol on an instrument shows that the surface may be hot Avoid personal contact to prevent bur...

Page 7: ...connections local sensing non floating 1 CHANNEL A and CHANNEL B 1 CHANNEL A and CHANNEL B Triax connectors 2 DIGITAL I O 2 DIGITAL I O 3 IEEE 488 3 IEEE 488 4 Cooling exhaust vent 4 Cooling exhaust v...

Page 8: ...A two wire connections local sensing Four wire Connections Model 2636A four wire connections remote sensing Model 2602A 2612A four wire connections remote sensing DUT LO CHANNEL A LO G LO HI G G G HI...

Page 9: ...00 Reference Manual section 10 for more information Step 6 Make measurements 1 Observe the readings on the display Press TRIG if necessary to trigger the unit to begin taking readings For the single c...

Page 10: ...irst Entering an incorrect IP address can prevent your PC from connecting to your corporate network 1 Open the Internet Protocol Properties dialog box In Windows 2000 a Click the Start button and open...

Page 11: ...rom within the LAN MENU a Select CONFIG IP ADDRESS b Refer to the recorded computer s IP address You will use a portion of the computer s address as a base for the instrument s unique ID Only the last...

Page 12: ...ress box EXAMPLEIf the instrument s IP address is 192 168 0 3 enter 192 168 0 3 in the browser s address box NOTE For computers do not enter any leading or trailing zeros 3 Press ENTER on the PC keybo...

Page 13: ...ur 2600A Quick start menu of TSP Express includes pre configured tests for common SMU functionality such as sweeps pulse and sequential source measure see help content on the right column for detail d...

Page 14: ...Meter Instruments Quick Start Guide 3 Assign the SMUs smua for voltage step on Gate and smub for voltage sweep on Drain 4 Set Step and Sweep Parameters 5 Click Run Step 4 View the data Data can be vie...

Page 15: ......

Page 16: ...of Keithley Instruments Inc All other trademarks and trade names are the property of their respective companies A G R E A T E R M E A S U R E O F C O N F I D E N C E Keithley Instruments Inc Corporate...

Reviews: