REMOTE
CONTROL
65
Return parameter <Boolean>
Returns the buzzer status.
SYSTem:CONFigure:BLEeder[:STATe]
Description
Sets or queries the status of the bleeder resistor.
Syntax
Query Syntax
SYSTem:CONFigure:BLEeder[:STATe] {OFF|ON|0|1}
SYSTem:CONFigure:BLEeder[:STATe]?
Parameter
0
<NR1> Turns the bleeder resistor off.
OFF
Turns the bleeder resistor off.
1
<NR1> Turns the bleeder resistor on.
ON
Turns the bleeder resistor on.
Return parameter <Boolean>
Returns bleeder resistor status.
SYSTem:CONFigure:BTRip[:IMMediate]
Description
Trips the power switch trip (circuit breaker) to
turn the unit off (shut down the power).
Syntax SYSTem:CONFigure:BTRip[:IMMediate]
SYSTem:CONFigure:BTRip:PROTection
Description
Enables/Disables the power switch trip (circuit
breaker) when the OVP or OCP protection settings
are tripped. This setting only applies after power
has been cycled.
Syntax SYSTem:CONFigure:BTRip:PROTection
{DISable|ENABle|0|1}
Query Syntax
SYSTem:CONFigure:BTRip:PROTection?
Parameter
0
<NR1> Enables the power switch trip for
OVP or OCP.
DISable
Disables the power switch trip for OVP or
OCP.
1
<NR1> Disables the power switch trip for
OVP or OCP.
ENABle
Enables the power switch trip for OVP or
OCP.
Set
Query
Set
Set
Query