Section 5: SCPI command reference
Series 2230G Triple-Channel Power Supplies User's Manual
5-8
2230G-900-01 Rev. A / June 2018
*SRE
This command sets or queries the bits in the Status Byte Enable Register. Setting this parameter can determine
which byte of the Status Byte Register has a value of
1
. The byte sets the RQS bit of the Status Byte Register
to
1
. The bit definition of the Status Byte Enable Register is as the same as the Status Byte Register.
Group
Status
Syntax
*SRE <NR1>
*SRE?
Arguments
<NR1>
An integer value
0
to
255
. The binary bits of the Status Request Enable Register (SRER) are
set according to this value. Using an out-of-range value causes an execution error.
Default value
The power-on default for the SRER is
0
if the
*PSC
command is set to
1
. If the
*PSC
command is set
to
0
, the SRER maintains its value through a power cycle.
Returns
An integer value from
0
to
255
.
Example
*SRE 48
Sets the bits in the SRER to a binary value of 00110000.
*SRE?
Might return a value of
32
, which means the bits in the SRER have the binary value 00100000.
See also
(on page 5-2)
(on page 5-3)