PAGE 4

T e c a l  1 4 0 F,  T e c a l  4 2 5 F  a n d  T e c a l  6 5 0 F  O P E R A T O R ’ S  M A N U A L

Introduction

Please read all the information in this booklet before using
the unit.

Warning

HIGH TEMPERATURES ARE DANGEROUS: they can
cause serious burns to operators and ignite combustible
material.
Techne have taken great care in the design of these units
to protect operators from hazards, but users should pay
attention to the following points:

USE CARE AND WEAR PROTECTIVE GLOVES TO
PROTECT HANDS;

DO NOT put hot objects on or near combustible
objects;

DO NOT operate the unit close to inflammable liquids
or gases;

DO NOT place any liquid directly in your unit;

At all times USE COMMON SENSE.

Operator Safety

All users of Techne equipment must have available the
relevant literature needed to ensure their safety.
It is important that only suitably trained personnel operate
this equipment, in accordance with the instructions
contained in this manual and with general safety standards
and procedures.  If the equipment is used in a manner not
specified by Techne the protection provided by the
equipment to the user may be impaired.
All Techne units have been designed to conform to
international safety requirements and are fitted with an
overtemperature cutout.  On some models, the cutout is
adjustable and should be set to suit the application.  On all
other models the cutout is preset to protect the unit.
If a safety problem should be encountered, switch off at the
mains socket and remove the plug from the supply.

Installation

1.

All Techne units are supplied with a power cable.  This
may be integral or plug-in.

2.

Before connecting the mains supply, check the voltage
against the rating plate. Connect the mains cable to a
suitable plug according to the table below.  

Note that

the unit must be earthed to ensure proper electrical
safety.

Connections

220/240V

110/120V

Live

Brown

Black

Neutral

Blue

White

Earth

Green/yellow Green

The fused plug supplied with the mains lead for use in
the UK is fitted with the following value fuse to protect
the cable:

230V UK

10 AMP

The fuse in the unit protects the unit and the operator.
Note that units marked 230V on the rating plate work
at 220V; units marked 120V work at 110V.  In both
cases, however, the heating rate will degrade by
approximately 8%.  The rating plate is on the rear of the
unit.

3.

Plug the mains cable into the socket on the rear of the
unit.

4.

Place the unit on a suitable bench or flat workspace, or
in a fume cupboard if required, ensuring that the air
inlet vents on the underside are free from obstruction.

5.

Note that the following symbols may be next to the
indicator lamps on the front panel of the units and have
the following meanings:

: the power indicator

: the heater indicator

: the overtemperature indicator

6.

Symbols on or near the power switch of the unit have
the following meanings:

 I

: mains switch On

O

: mains switch Off

After use

When you have finished heating samples, remember that
parts of the unit – the tubes, blocks and associated
accessories –  may be very hot. Take the precautions listed
earlier.

Guarantee

The unit is guaranteed against any defect in material or
workmanship for the period specified on the enclosed
guarantee card. This period is from the date of purchase,
and within this period all defective parts will be replaced
free of charge provided that the defect is not the result of
misuse, accident or negligence. Servicing under this
guarantee should be obtained from the supplier.
Notwithstanding the description and specification(s) of the
units contained in the Operator’s Manual, Techne hereby
reserves the right to make such changes as it sees fit to the
units or to any component of the units.
This Manual has been prepared solely for the convenience
of Techne customers and nothing in this Instruction Book
shall be taken as a warranty, condition or representation
concerning the description, merchantability, fitness for
purpose or otherwise of the units or components.

User maintenance

NOTE THAT THIS EQUIPMENT SHOULD ONLY BE
DISMANTLED BY PROPERLY TRAINED PERSONNEL.
REMOVING THE SIDE, FRONT OR REAR PANELS
EXPOSES POTENTIALLY LETHAL MAINS VOLTAGES.
THERE ARE NO USER MAINTAINABLE PARTS WITHIN
THE EQUIPMENT.
In the unlikely event that you experience any problems with
your unit which cannot easily be remedied, you should
contact your supplier and return the unit if necessary.
Please include any details of the fault observed and
remember to return the unit in its original packing.  Techne
accept no responsibility for damage to units which are not
properly packed for shipping: if in doubt, contact your
supplier.  See the Decontamination Certificate supplied
with your unit.

1. Cleaning

Before cleaning your unit ALWAYS disconnect from
the power supply and allow to cool below 50° C.
Your unit can be cleaned by wiping with a damp soapy
cloth.  Care should be exercised to prevent water from
running inside the unit.  Do not use abrasive cleaners.

2. Fuses

Your unit is protected by one or two fuses.  These
should only be changed by suitably qualified personnel.
If the fuses blow persistently, a serious  fault is indicated
and you may need to return the unit to your supplier for
repair.

Summary of Contents for TECHNE Tecal 140F

Page 1: ...Issue 2 Date of issue 3rd May 2005 Techne is a trademark Techne 2003 Tecal 140F Tecal 425F and Tecal 650F Calibrators Operator s Manual...

Page 2: ......

Page 3: ...ion 9 Specification Tecal 140F 10 Specification Tecal 425F 11 Specification Tecal 650F 12 WHEN YOU SWITCH ON 13 Front Panel controls 13 Setting the Units for Temperature 13 Setting the Operating Tempe...

Page 4: ...PAGE 2 T e c a l 1 4 0 F T e c a l 4 2 5 F a n d T e c a l 6 5 0 F O P E R A T O R S M A N U A L...

Page 5: ...PAGE 3 T e c a l 1 4 0 F T e c a l 4 2 5 F a n d T e c a l 6 5 0 F O P E R A T O R S M A N U A L NOTES...

Page 6: ...if required ensuring that the air inlet vents on the underside are free from obstruction 5 Note that the following symbols may be next to the indicator lamps on the front panel of the units and have t...

Page 7: ...tte d aspiration en s assurant que les trous d a ration situ s sous l appareil ne sont pas obstru s 5 Les symboles ci dessous situ s c t des t moins lumineux sur la face avant de l appareil ont la sig...

Page 8: ...ungsanleitung komplett bevor Sie dieses Ger t benutzen Warnung HOHETEMPERATURENSINDGEF HRLICH siek nnen dem Bediener ernsthafte Verletzungen zuf gen und brennbare Materialien k nnen sich leicht entz n...

Page 9: ...e pueden aparecer junto a las luces indicadoras en el panel frontal del equipo tienen los siguientes significados Indicador de potencia Indicador del calor Indicador de sobretemperatura 6 Los s mbolos...

Page 10: ...obe sizes these are detailed towards the back of this manual Maintaining a set temperature The required temperature is set on the calibrator and the operation of the probe is checked ukAS certificate...

Page 11: ...ginal packing in case you ever need to return it for service or repair When returning a unit remember to remove the insert from the temperature controlled block The unit must be transported in the ori...

Page 12: ...2 C 0 36 F Temperature stability after 10 minutes 0 05 C 0 09 F Display resolution 0 01 C 0 1 F Set point display resolution 0 1 C 0 1 F Heat up rate 5 minutes 20 C to 100 C 68 F to 182 F Cool down ra...

Page 13: ...ability at 200 after 10 minutes 0 03 C 0 054 F Temperature stability at 425 after 10 minutes 0 05 C 0 09 FDisplay resolution 0 01 C 0 1 F Set point display resolution 0 1 C 0 1 F Heat up 12 minutes 20...

Page 14: ...ormity 1 C 1 8 F Temperature stability after 10 minutes 0 09 C 0 16 F Display resolution 0 01 C 0 1 F Set point display resolution 0 1 C 0 1 F Heat up 35 minutes 20 C to 600 C 68 F to 1112 F Cool down...

Page 15: ...llows It will display this for 1 second then the actual temperature of the block will be indicated The Front Panel Controls The front panel controls consist of three buttons for controlling the displa...

Page 16: ...ock Indicator The next indicator shows when there is power to the block When the set temperature is different to the block temperature this indicator will light If the light is on continuously the blo...

Page 17: ...en them The display may reach temperature in 2 or 3 minutes while the insert may take 5 minutes or more to reach temperature After Use 1 When you have finished heating samples remember that parts of t...

Page 18: ...d the PC before either unit is powered up otherwise data integrity cannot be guaranteed Once the cable is fitted it does not matter which unit is powered up first ON OFF switch RS232 9 way PC serial p...

Page 19: ...e calibrator should be returned to your supplier for repair Over temperature Cut out If the over temperature cut out trips it can be reset by switching the unit off waiting a few seconds then switing...

Page 20: ...requires an insert with a 10mm diameter or larger hole 6103890 RS232 Cable only Inserts Tecal 140F and Tecal 425F Inserts are made from aluminium or aluminium bronze and must be ordered separately fro...

Page 21: ...lled to suit your application Aluminium Bronze Inserts Immersion Depth 152 4 mm or 6 NUMBER PROBE DIAMETER METRIC FINSABA 5 off 6mm FINSABB 1 off each 10mm 8mm 6mm 4 5mm 3mm FINSABC 2 off 6mm 2 off 10...

Page 22: ...PAGE 20 T e c a l 1 4 0 F T e c a l 4 2 5 F a n d T e c a l 6 5 0 F O P E R A T O R S M A N U A L NOTES...

Page 23: ...g the details below UK Office Keison Products P O Box 2124 Chelmsford Essex CM1 3UP England Tel 44 0 330 088 0560 Fax 44 0 1245 808399 Email sales keison co uk Please note Product designs and specific...

Reviews: