background image

EQUIPMENT YOU NEED

 

 

Before assembling your new Keiser M3 indoor cycle obtain the following tools: 

 

Torque wrench (Minimum 45 Nm / 35 ft-lb)  

 

4” extension 

 

15mm open-end wrench

 

16mm, or 5/8” open-end wrench

 

#2 Phillips screwdriver

 

15mm crowfoot

 

16mm, or 5/8” crowfoot 

 

5mm Allen Wrench

 

6mm Allen Wrench

 

Paste or spray wax (used to clean after assembly)

 

Clean cloth

NOTICE 

Users,  agents  or  anyone  directing  the  use  of  this  equipment  shall  determine  the  
suitability of the product for its intended use, and said parties are specifically put on 
notice that they shall assume all risk and liability in connection herewith. 

555500 B

UNPACKING THE BIKE

 

 

Carefully remove the bike from the cardboard box. Lay-out all the components and check to 
assure all parts are present and undamaged. If parts are missing or damaged contact your 
local dealer, distributor or Keiser Corporation Service Department.

           

NOTE: 

The substitution or modification of any part or component, other than what is  

           approved by Keiser, will void your warranty. 

After unpacking and verifying parts, you are ready to start your assembly. You need an area 
that is free of dirt, dust or other foreign material that could impair the assembly of your 
bike.

Always follow the steps in this manual as you assemble your bike. Do not skip, substitute or 
modify any steps or procedures of this assembly, as doing so could result in personal injury 
and will void your warranty. We have put a number of precautions in this manual. 

WARNING:

  Indicates  a  potentially  hazardous  situation  which,  if  not  avoided,  could 

result  in  serious  injury.  By  not  heeding  these  warnings,  the  warranty  will  be  void.  

NOTE:

 Informs you about things we recommend you do or are aware of, before performing 

the assembly. These notes are placed in the manual to aid you during a certain procedure or 
to make you aware of any general mandatory actions or information. 

ASSEMBLY MANUAL

BEFORE ASSEMBLING

A

B

C

E

F

G

H

K

L

NOTE: Since we are always striving to improve our products; our products are 
subject to change without notice.

CHECKING FOR PROPER OPERATION

Pre-Ride Checklist

 

Please inspect bike carefully and thoroughly before riding.

 All Parts Correctly Installed

 Acorn Nuts Torqued At 45 Nm (35 ft-lbs)

 Pedals Loctited and Torqued To 45 Nm (35 ft-lbs)

 All Screws and Nuts Properly Torqued and Tightened

 Handlebar and Seat Adjustments Operate Properly 

 Bike Has Been Polished With Paste or Spray Wax and a Clean Cloth

� 

Computer Installed and Calibrated and In Working Order   

      (Models With Computers) (See “Calibrating The Computer”)

Test Ride

Your bike should now be ready to test ride.

1. Adjust the seat and handlebar for proper height and comfort.
2. Secure your feet in the pedals.
3. Move the shifter toward yourself and down and begin pedaling.
4. The computer should wake up and display “ODO” and total distance ridden  

    

     across the bottom. After approximately 10 secs “ODO” will change to gear  
     and trip.
5. Now move the shifter up and note the gear changing on the computer and the 
     resistance getting harder.
6. Ride at various speeds and resistances to check for noise and vibration.
7. Move the shifter to full forward position to check that the emergency brake  
    stops the flywheel from turning.
8. You have completed the test.
9. Enjoy your ride.

If you experience any problems please contact our Service Department 
 

(USA) 1-800-888-7009 (International) 559-256-8000 
www.keiser.com/service/ 
[email protected]

WARNING: 

Perform the operation below before riding to make sure 

the bike is fully operational. Failing to test a bike prior to normal 
use will void your warranty and could result in serious injury.

PARTS INVENTORY

 

A) Handlebar Assembly
B) Base Frame
C) Bike Frame
D) Flywheel
E) 2-Pedals/1-Loctite 242
F) Hubcap
G) 4 Acorn Nuts 
H) 4 Washers
J ) 5 Socket Head Cap Screws  
     M6x1 X 20 SS
K ) 2 Socket Head Cap Screws  
     M8x1.25 X 12 SS 
L) Computer (models with computer only)

(800) 888-7009 keiser.com