background image

08

AIR350 BIAXIAL UPPER BACK 

OPERATION MANUAL

INSTALLATION AND PLACEMENT 

TRAINING SPACE

Figure 4. Training Space for the Air350 Biaxial Upper Back

The equipment footprint is 51 inches x 48 inches (1,296 mm x 1,219 mm). The minimum recommended free space around the 
equipment is 24 inches (610 mm) for the front and sides.

Figure 3. How to Connect the Equipment to 

the Keiser Air Supply

Note: Additional Free Space may be required to accommodate mobility device access.

No assembly required. Place the Air350 Biaxial Upper Back on a flat, level surface. Make sure the base of the frame 
makes full contact with the floor. If gaps are present, relocate the equipment to an even surface.

CONNECT THE EQUIPMENT TO THE KEISER AIR 
SYSTEM

WARNING: Never connect equipment to an air 

source capable of exceeding 120 psi / 8.27 bar.

 

Over pressurizing Keiser pneumatic equipment may 
cause tubing to burst, breakage of equipment, 
abnormal operation, or serious injury. Use only clean, 
dry, regulated compressed air at the rated pressure 
range of 100–120 psi / 6.89–8.27 bar.

1.  Plug the Compressor into the appropriate power 

source to power the Compressor ON

 (allow the 

Compressor to build up to a minimum of 100 psi / 
6.89 bar; Keiser Compressor and Keiser Air System 
not included, sold separately)

.

2.  Connect the 1/4-inch Quick Disconnect (QD) 

from the equipment into the Keiser Air Supply 

(see Figure 3)

.

FREE AREA

FOOTPRINT

24 inches 

(610 mm)

24 inches 

(610 mm)

24 inches 

(610 mm)

Keiser Air System

(floor or wall air outlet)

Direct-connect to
Keiser Small Air Compressor

Keiser

Large Air Compressor

Keiser

Small Air Compressor

1/4-inch QD

48 inches 

(1,219 mm)

51 inches 

(1,296 mm)

Summary of Contents for 002035BP

Page 1: ...BIAXIAL UPPER BACK OPERATION MANUAL AIR350 STRENGTH CARDIO FUNCTIONAL MODELS 002035BP 002035SP...

Page 2: ...AINTENANCE 19 REGULATORY AND COMPLIANCE NOTICES 19_SAFETY NOTIFICATIONS 20_ELECTROMAGNETIC COMPATIBILITY EMC 20_US FCC COMPLIANCE STATEMENT 20_DISPOSAL 23 WARRANTY STATEMENT Keiser the Keiser logo and...

Page 3: ...stay informed of safety notifications and for faster more accurate warranty service Scan the QR Code to the right to access the interactive online warranty registration form or visit https www keiser...

Page 4: ...these instructions could result in injury 15 Always maintain control of the Handles Exercise Arms during exercise The sudden release of the Exercise Arms during exercise will cause the Exercise Arms t...

Page 5: ...us situation that if not avoided could result in minor or moderate injury IMPORTANT Indicates information considered critical but not hazard related IMPORTANT SAFETY INFORMATION Maintain and do not re...

Page 6: ...gerous heart arrhythmias at rest or aortic aneurysm If the patient is experiencing acute illness febrile condition i e fever or newly occurring pain this represents an absolute contraindication for ph...

Page 7: ...hes 1 219 mm 51 inches 1 296 mm 63 inches 1 600 mm 240 lbs 109 kg EQUIPMENT SPECIFICATIONS Figure 2 Air350 Biaxial Upper Back Equipment Specifications See Figure 2 for Air350 Biaxial Upper Back dimens...

Page 8: ...YSTEM WARNING Never connect equipment to an air source capable of exceeding 120 psi 8 27 bar Over pressurizing Keiser pneumatic equipment may cause tubing to burst breakage of equipment abnormal opera...

Page 9: ...Biaxial Upper Back Power Display Adjustable Seat Increase Decrease Thumb Buttons Air Tank Quick Disconnect QD with Tube Footrest Instruction Placard not shown Spring Pin Chest Pad Adjustment Processo...

Page 10: ...r also deletes the current workout data from the eChip System Messages appear in the RESISTANCE window OFF low power consumption sleep mode Sleep mode occurs after 60 seconds of machine inactivity to...

Page 11: ...nt data indicates no data was input to record Settings can only be changed immediately after the eChip is inserted and before your third rep After three reps are performed the setting cannot be change...

Page 12: ...ains blank see Battery Replacement procedure page 17 A Thumb Buttons and Display press Thumb Buttons to check for proper operation and the Display powers on B Exercise Arms move freely no loose parts...

Page 13: ...mb Buttons are in line with the middle of your chest 2 Adjust the Chest Pad until the Handgrips Thumb Buttons are at an extended reach 3 Adjust the resistance with the Thumb Buttons 1 2 3 Figure 9 How...

Page 14: ...y Pull the elbows back fully and at the same time move arms at the same level Keep your body in an upright position and in contact with the Seat and Chest Pad during movement ECCENTRIC PHASE OUTWARD M...

Page 15: ...ance high speed 80 90 of your maximum SET 2 Three repetitions Low resistance high speed 10 of your maximum SET 1 START TEST Press and hold both Thumb Buttons release when 6 r appears in the RESISTANCE...

Page 16: ...TE Your Keiser Air Compressor not included with your Air350 Biaxial Upper Back requires basic annual maintenance Contact Keiser Customer Support for Air Compressor operator manual or download at keise...

Page 17: ...artment insert the 2 new D batteries into the battery sleeve and install The Power Display will enter a brief test sequence youwillseeaseriesofnumbers flashing 4 Replace the Processor Box cover and sc...

Page 18: ...element turns a bright pink or red color Tools required Small Needle Nose Pliers Cutter Tool to cut off flared end of tubes 6 Lubricate Cylinder Rods Wipe the Cylinder Rods clean and coat lightly wit...

Page 19: ...sociated with the disposal of waste products residues including disposal of the equipment itself at the end of its useful life The Air350 Biaxial Upper Back contains electronic circuit assemblies 2 al...

Page 20: ...ELECTROMAGNETIC COMPATIBILITY EMC DISPOSAL This equipment contains electrical or electronic components alkaline batteries and a sealed lithium coin cell battery that must be disposed of properly to c...

Page 21: ...21 AIR350 BIAXIAL UPPER BACK OPERATION MANUAL This page intentionally left blank...

Page 22: ...22 AIR350 BIAXIAL UPPER BACK OPERATION MANUAL This page intentionally left blank...

Page 23: ...nday Friday 7 am to 5 30 pm PST or by email at service keiser com Customers outside the United States may obtain warranty information directly through a Keiser international distributor or dealer in t...

Page 24: ...after reading this manual contact Keiser Customer Support 205500_C 1 559 256 8000 service keiser com keiser com support Telephone and Live Chat Monday Friday 7 am to 5 30 pm PST 24 AIR350 BIAXIAL UPPE...

Reviews: