8
Chapter 2. Setup
The following illustration shows MCB167-NET board and the important
interface and hardware components.
Configuring the MCB167-NET
You configure the MCB167-NET evaluation board with the DIP switches and
the configuration jumpers. The MCB167-NET evaluation board is shipped with
the following configuration:
20 MHz internal CPU clock, 3 chip select signals, 4 segment address lines.
enabled bootstrap loader for downloading the debug monitor,
enabled CAN drivers and CAN bus termination resistors,
5V reference voltage for the A/D converter.
The default DIP switch settings are shown in the following table.
Switch
CLKCFG
SALSEL
CSSEL
BTYP
BSL
ON
X
X
X
X
X
X
X
OFF
X
X
X
Power Supply
DC 9V 500mA
ASC0
Serial Jack
DIP
Switches
CAN
connectors
NMI Interrupt
Button
1 MByte
SRAM
Infineon C167 or
ST10-167/168 variant
LED’s for Power and Port P2.0 .. P2.7 Status
Prototyping
Area
Port & Bus
Signals
Configuration
Jumpers
Reset Button
Sockets for
Flash ROM
Summary of Contents for MCB167-NET
Page 18: ...18 Chapter 3 Hardware Schematics...
Page 19: ...MCB167 NET Board User s Guide 19...
Page 20: ...20 Chapter 3 Hardware...
Page 21: ...MCB167 NET Board User s Guide 21...