DEVICE REGISTRATION 

Once you have made a RAPT account you will need to connect your RAPT Fermentation Chamber to 
your Wi-Fi network. 

Open your network and internet settings on your mobile device, tablet or computer and connect to 
the KegLand RAPT wifi network using the password shown on the screen on your RAPT Fermentation 
Chamber. 

This will allow you to connect your RAPT Fermentation Chamber to your wifi network. 

Once your RAPT Fermentation Chamber is connected to your wifi network you will then need to 
register your device with your RAPT account. 

When prompted on the screen, press the select (

)

 button to enter the main menu then select 

“Register Device”.

 

Select “Add new Device” then select “RAPT Fridge” within the RAPT portal and follow the prompts to 

register your device.  

Note: The MAC address and Validation code will be displayed on the screen of your RAPT 
Fermentation Chamber during Device Registration. 

Once you have registered your device with your RAPT account you will be able to change the target 

temperature manually on the RAPT Fermentation Chamber using the “Up” or “Down” arrows or 

change the target temperature through the RAPT portal.  

For detailed instructions regarding use of the RAPT portal please refer to the following instructional 
YouTube video: 

https://www.youtube.com/watch?v=MzMYYmGM2ik 

 

INSTALLING duotight BLOWTIE or INLINE REGULATOR (optional) 

If you intend to pressure ferment in the RAPT Fermentation Chamber you may find it useful to install 

KL15042 duotight BlowTie Spunding Valve

 and/or a 

KL15035 duotight Inline Regulator

. 

The duotight BlowTie Spunding Valve will allow excess pressure built up during fermentation to be 
released from the fermenter allowing an optimal fermentation pressure to be set based on your 
beer style and recipe. 

Installation of a duotight inline regulator allows for easy pressurisation for closed transfers for 
example. 

There is a mounting point on either side of the RAPT temperature controller for mounting a duotight 
BlowTie Spunding Valve or Inline Regulator. 

Summary of Contents for RAPT KL15813

Page 1: ...RAPT Fermentation Chamber Instruction Manual Page 1 of 13 www KegLand com au Last Updated 1 03 2022 4 36 PM Fermentation Chamber Fridge KL15813 Instruction Manual KegLand Distribution PTY LTD...

Page 2: ...E UPRIGHT POSITION FOR 24 HOURS BEFORE PLUGGING INTO MAINS POWER SOCKET WARNING ALWAYS THOROUGHLY CHECK FOR GAS LEAKS ONCE YOU HAVE SET UP YOUR SYSTEM WARNING CO2 GAS CAN BE DANGEROUS MAKE SURE TO ALW...

Page 3: ...u or your nearest KegLand Distributor for more assistance Important Let the RAPT Fermentation Chamber Fridge sit upright for at least 24 hours after delivery or after sitting the unit on its side befo...

Page 4: ...ivity of the RAPT Fermentation Chamber you will need to sign up for an account on the RAPT portal This will allow you to create custom fermentation profiles track and monitor your fermentation tempera...

Page 5: ...RAPT Fermentation Chamber during Device Registration Once you have registered your device with your RAPT account you will be able to change the target temperature manually on the RAPT Fermentation Ch...

Page 6: ...egulator is pointing towards the RAPT temperature controller Side mounting 1 Push a 6mm x 8mm reducer onto the duotight compatible barb of the carbonation cap 2 Cleanly cut an 84mm length of EVABarrie...

Page 7: ...ANEL TO ACCESS THE DRIP TRAY The front panel at the base of the RAPT Fermentation Chamber is dismountable In normal use it is held in place by magnets to allow easy and convenient access to the drip t...

Page 8: ...ture within the RAPT Fermentation Chamber If you were looking for higher accuracy temperature measurement by inserting a temperature probe into the thermowell of your fermenter you will need to instal...

Page 9: ...m right hinge Perform this in reverse to install the left hinges Install the left bottom hinge Carefully align the door onto the left bottom door hinge pin Then install the left top hinge and replace...

Page 10: ...profile Rewind and Forward allow you to move forward or backwards along the profile Play Pause allows you to pause or resume the active profile Stop will stop the current profile Manual alterations t...

Page 11: ...compressor Mode Switch Delay This sets the minimum allowed time between mode changes IE from Heating to Cooling A minimum of at least 30 minutes is often more suitable for fermentation to avoid unnece...

Page 12: ...ture probe if known The default is 100000 PID Heating This will toggle PID heating mode on or off Note PID control is recommended for advanced users and is not required for typical fermentation PID Cy...

Page 13: ...require little ongoing maintenance Periodically check the undermounted drip tray and empty as needed The outside of the RAPT Fermentation Chamber can be cleaned with a microfibre cloth The inside of t...

Reviews: