LEAK TESTING
GENERAL
Although the gas connections of the appliance are leak tested prior packing and shipment, a
complete test must be performed before use.
Before each use, check all the gas connections for leaks using the procedure outlined below. If the
smell of gas is detected at any time, you should immediately stop using and check the entire system
for leaks.
BEFORE TESTING
Make sure all packing material has been removed from the appliance.
Make a solution of one part liquid detergent and one part water. You will need a spray bottle, brush
or rag to apply the solution to the fittings.
TO TEST
1. Turn the burner valve OFF
2. Turn the liquid propane cylinder valve ON (counter-clockwise) to open the valve.
3. Apply the soap solution to all gas fittings and connection. Soap bubbles will appear where a leak is
present.
4. If a leak is present, immediately turn the gas supply OFF and tighten leaking fittings or connection.
5. Turn the gas back ON and recheck.
6. Should the gas continue to leak from any of the fittings, turn the gas supply OFF and contact your
point of sale for support.