Heating Relay Instructions
Each temperature controller contains heating terminals as
standard which a heating device can be wired into. To do this
a certified electrician can use the following steps:
Step 1.
Unplug the power source for the heating
device and the G40 chiller.
Step 2.
Locate and cut the active wire to your heating
device (see diagram to the right). Most active wires
are brown or red but this should be double checked
with an electrician.
Step 3.
Divert the active wire into the blade connects (terminals 4 and 5 shown below)
Step 4.
Plug both the G40 and heating device into mains power
NOTE: This is the same process for all four temperature controllers. So repeat this step to
wire multiple controllers in the same way.
WARNING
ENSURE All WORKS ARE CARRIED OUT BY OR INSPECTED BY A CERTIFIED