3. Press the service button. LED starts flash slowly and you can enter new PIN code.
- if the LED will flash so many times which is the new value of first PIN number, press
service button once. First digit of new PIN code is save. LED will start to flash again.
- if the LED will flash so many times which is the new value of second PIN number,
press service button once. Second digit of new PIN code is save. LED will start to
flash again.
- if the LED will flash so many times which is the new value of third PIN number, press
service button once. Third digit of new PIN code is save. LED will start to flash again.
- if the LED will flash so many times which is the new value of fourth PIN number, press
service button once. Fourth digit of new PIN code is save. LED will start to flash again.
- 5 seconds after fourth digit is entered, LED diode automatically display new PIN code
by the number of flashes. Display first digit of code, 2 sec. pause, display second digit
of code, 2 sec. pause etc...
4. Turn ignition ON or system will automatically ends programming of new PIN code
after 10 seconds from displaying the new PIN code.
PIN CODE RESET
Disconnect system from power. Disconnect the jumper in the control unit and connect
the system to the power supply. Within 3 seconds, connect the jumper in the control
unit. PIN code is set to the default setting (4321).
IX.
PROGRAMMING REMOTE CONTROLS
1. Turn ignition ON and press service button 5 times within 8 seconds. Turn ignition OFF.
If security mode is not active, siren beeps 5 times, system is now set to programming
mode and LED starts flash. If security mode is active (function F19), enter it by 4 digits
PIN code. LED starts flash slowly.
- if the LED will flash so many times which is the value of first PIN number, push the
service button one time. LED will start to flash again.
- if the LED will flash so many times which is the value of second PIN number, push
the service button one time. LED will start to flash again.
- if the LED will flash so many times which is the value of third PIN number, push the
service button one time. LED will start to flash again.
- if the LED will flash so many times which is the value of fourth PIN number, push
the service button one time.
If you entered correct PIN code, siren beeps 5 times and now you enter to the
programming mode. LED starts flash fast.
2. Press any of button on remote control within 5 seconds. If you dont press any of
button within 5 seconds or ignition will be turned ON, system automatically ends
programming.
3. Siren confirms programming by short beep. Depending on which controller was
programmed, so many times siren beeps. Successful programming of first remote
control siren confirms by one beep, second remote control siren confirms by two
beeps, etc...
4. If you want to program new remote control, you must also re-program all remotes,
which are already programmed in system.
5. System allows you to porgram up to 10 remote controls. When programming new
remotes system automatically erase already programmed remotes.
X. SETTING THE INTENSITY OF CAR-JAMMING CONTROL
Intensity of car-jamming control when system activation can be set in 5 levels. Level 1, 3,
6, 9, 11. The most sensitive level is 1 (factory set).
Intensity set:
1. Activate service mode and turn ignition ON.
2. Press service button 3 times within 5 sec. and turn ignition OFF, siren beeps 3 times
and LED diode flashing.
3. Press service button, siren beeps once. Save new settings by turning ignition ON, and
siren beeps so many times, which is the new value of intensity. If you want to change
the settings, proceed from point 2.
4. Exit service mode.
XI. PROGRAMMING CAR ALARM VIA PC
It is possible to program TS 100-50 car alarm via PC. To connect car alarm with PC and
set parameters via PC, you need T PROG programming cable and KEETEC TS100-50
PC Setup, which must be installed before alarm connection. After installation of T PROG
cable and TS100-50 PC Setup software is everything ready for programming.
TS 100-50 programming process:
- connect car alarm to the power supply
- connect car alarm with PC using T PROG cable
- run KEETET TS 100 - 50 PC Setup
- select COM port, which is allocated to the programming cable T PROG and select the
language
- click on
Load
to view actual settings of car alarm
- change settings of car alarm and click on
Apply
. New values will be saved to car
alarm and system is now programmed
- if you want to set car alarm to factory settings, click on
Default
and after loading factory settings values, save them by clicking on
Apply
- it is possible to set security PIN code via PC Setup. Click on
Load
to load actual PIN
code
F18. SIREN TYPE
PRE-SET: normal siren
ADJUSTABLE: coded siren
F19. SECURITY MODE
PRE-SET: security mode is deactivated
ADJUSTABLE: security mode is active. It is necessary to enter PIN code when security
mode is active for programming system function or for emergency deactivation of
system.
F20. AUTOMATIC REACTIVATION
PRE-SET: function is allowed. If you do not open any door after deactivation, system
automatically activate after 30 seconds. If function F16 is turned on, central locking
system will lock itself when automatic reactivation is active.
ADJUSTABLE: function is prohibited
F21. OUTPUT NO.1
PRE-SET: pager output is active throughout the duration of an alarm
ADJUSTABLE: immobilization output - output is active after alarm activation
F22. OPTICAL SIGNALIZATION WHEN ACTIVATE/DEACTIVATE
PRE-SET: optical signalization is allowed
ADJUSTABLE: optical signalization is prohibited
F23. LOCK CHECK WHEN SIGNAL JAMMING
PRE-SET: function is prohibited
ADJUSTABLE: function is allowed - system is checking presence of jamming signal for
10 seconds after closing doors. If system detects jamming signal, siren beeps 3 times.
F24. CAN BUS ACTIVATION/DEACTIVATION
PRE-SET: function is allowed - system is activate/deactivate via CAN BUS
ADJUSTABLE: function is prohibited
F25. ULTRASONIC SENSOR
PRE-SET: ultrasonic sensor is activated
ADJUSTABLE: ultrasonic sensor is deactivated
F26. PANIC ALARM BY ORIGINAL REMOTE CONTROL
PRE-SET: if you press lock button for 3 times within 5 seconds, PANIC alarm is active.
Function is available only for CAN BUS connection of supported vehicles!
ADJUSTABLE: PANIC alarm is prohibited
F29. IMMOBILIZATION RELAY
PRE-SET: NO - immobilization circuit is using contacts marked NO and COM. When
car alarm is deactivated, these contacts are linked after turning ignition ON.
ADJUSTABLE: NC - immobilization circuit is using contacts marked NC and COM.
When car alarm is deactivated, these contacts are permanent linked.
F30. SYSTEM RESET
System is reset and set to default factory settings,
except function F10!
VII. EMERGENCY DEACTIVATION
1. open driver door and turn ignition ON.
2. press the service button so many times, which is value of first digit of PIN code
within 10 seconds and turn ignition OFF. If security mode is disabled, siren beeps
twice, directional lights flashes twice and now system is deactivated. If security mode
is active (function F19), enter by 4 digits PIN code. LED starts flashing slowly.
- if the LED will flash so many times which is the value of first PIN number, push the
service button one time. LED will start to flash again.
- if the LED will flash so many times which is the value of second PIN number, push
the service button one time. LED will start to flash again.
- if the LED will flash so many times which is the value of third PIN number, push the
service button one time. LED will start to flash again.
- if the LED will flash so many times which is the value of fourth PIN number, push
the service button one time.
If you entered correct PIN code, siren beeps twice and directional lights flashes twice.
System is now deactivated.
VIII. PIN CODE CHANGE
1. Turn ignition ON and press service button 10 times within 10 seconds.
2. Turn ignition OFF. If security mode is deactivated, now you are in programming
PIN code menu. If security mode is active (function F19), enter it by entering 4 digits
PIN code. LED diode starts flashes slowly.
- if the LED will flash so many times which is the value of first PIN number, push the
service button one time. LED will start to flash again.
- if the LED will flash so many times which is the value of second PIN number, push
the service button one time. LED will start to flash again.
- if the LED will flash so many times which is the value of third PIN number, push the
service button one time. LED will start to flash again.
- if the LED will flash so many times which is the value of fourth PIN number, push
the service button one time.
If you entered correct PIN code, siren beeps once and LED diode turns OFF. Now you
are in PIN code programming menu.
- enter new PIN code to the window
New
- enter same digits to the window
Confirm
and click on
Apply
- end programming by click on
End
Car Alarm TS 100-50 contains the memory of events, in which triggered alarms are
recorded. The memory stores the last 20 alarms. Alarms memory can be seen in pro-
gramming software KEETET TS 100 - 50 PC Setup.
Memory of events TS 100-50:
- connect car alarm to power supply 12V
- connect car alarm with PC using T PROG cable
- run KEETET TS 100 - 50 PC Setup
- select COM port, which is allocated to the programming cable T PROG and select
the language
- click on
List of events
and then on
All Event
or
Current Event
according to if you
want to see all alarms or last one.
- memory of events can be erased by click on
Clear
KEETEC TS 100
CARALARM INSTALLATION MANUAL 2/2
EN
R
TECHNICAL PARAMETERS
Power supply
12V +/- 25%
Working temperature
from -30°C to 70°C
Current consumption (stand-by)
10mA
Working frequency
433,92 MHz
Alarm duration
30 seconds