TECHNICAL INFORMATION
Mirage technical manual
page 50 of 65
Level control and water meters
Figure T 3. The low voltage circuits that control water level (left) and pass water volumes towards the
Gicar controller (right) via the 7-pole connector. Note that in position 1 three (Duette) or four (Triplette)
individual leads are grouped. Similar for position 2.
Mains switch Duette
The 3x 3-way mains switch disconnects both neutral and phase from the power mains in position "0".
In position “1”, power is fed to the main controller but not to the heating element. The machine is only
fully functional in position "2" of the mains switch. Position "1" is very useful for testing and checking
various functions in the machine.
Figure T 4. The 3x 3-way switch used in the Mirage Duette 1-phase. In position 1 power is fed onto the
machine, but not onto the heating element. Only in position 2 is the element also connected to the
power mains (phase via the SSR).
GC:
Gicar 7-pole connector
GC
safety
level
operational
level
Duette:
Triplette:
water meters
right
left
middle
right
- -
7
6
5
4
3
2
1
left
0
+ -
0
+ -
0
+ -
2
R
S
T
2
2
1
1
1
connections are made in
position 1 and position 2
connections are made in
position 2 only
connector block 1&3
connector block 5&6
heating element
solid state relay
16A