![Kees van der Westen Mirage Slim Jim Installation Manual Download Page 13](http://html1.mh-extra.com/html/kees-van-der-westen/mirage-slim-jim/mirage-slim-jim_installation-manual_3883248013.webp)
INSTALLATION MANUAL
– install
Slim Jim Installation manual
page 12
Connect electric mains
Rated voltage: ~230V / 3N~400V, 50 / 60Hz
Rated power: max. 32.2 (230V) / 11.3 (400V) Amp per phase, see Table 2 for details.
The appliance is to be supplied through a residual current device (RCD) having a rated residual
operating current not exceeding 30mA.
Normally the mains cable will not have a plug attached to it. This is to allow for a smaller hole in the
countertop to feed the cable through.
The machine can be equipped with 3 different mains cables, see Figure 8.
3-phase
European:
5x 2.5mm
2
3x 7.8-11.3A
1-phase
European:
3x 6.0mm
2
25.2-32.2A
1-phase
USA:
3x 10AWG
25.2-32.2A
Figure 8. The 3 different main cables the machine can be equipped with.
Note that in the “alternative”
USA connection phase1 is described with -
115Vac meaning in “counterphase to phase2”.
Danger
If the supply cord is damaged it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
•
It is advised to check an existing wall socket before mounting a plug on the mains cable.
•
Disconnect electric power in the fuse box of the building if the machine is hooked straight into a
wall box.
•
Check if all switches on the machine are in the OFF position (toggle-lever pointing down).
•
Mount the cable directly into the wall connection box or mount the correct plug on the mains cable
and plug into existing wall socket.
•
Re-connect electric power in the fuse box.
If a 16A CEE 3P-N-E plug is already mounted on a new three-phase machine it will be connected as
in Figure 9.
looking from right into
the 16A CEE plug shown
on left
Figure 9. 16A CEE 3P-N-E plug mounted on mains cable.
earth
neutral
0Vac
phase1
230Vac
phase2
230Vac
phase3
230Vac
earth
neutral
0Vac
phase
230Vac
earth
earth
neutral
0Vac
or:
phase1
-115Vac
phase
230Vac
phase2
115Vac
E
N
P1
P2
P3
E
P2
P1
P3
N