INSTALLATION MANUAL
– check location
Slim Jim Installation manual
page 7
Electric mains
Rated voltage: ~230V / 3N~400V, 50 / 60Hz
Rated power: max. 34.7 (230V) / 11.6 (400V) Amp per phase, see Table 2 for details.
Danger
If the supply cord or the pump connection cord is damaged it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a hazard.
The appliance is to be supplied through a residual current device (RCD) having a rated residual
operating current not exceeding 30mA.
Slim Jim
peak power
at 230 Vac
version
per
phase
Duette
Triplette
Duette
Triplette
4800W steam power
6000W steam power
kW
Amp
kW
Amp
kW
Amp
kW
Amp
3-phase
(3N~400V)
L1
2.1
8.9
2.1
8.9
2.5
10.7
2.5
10.7
L2
2.1
8.9
2.1
8.9
2.5
10.7
2.5
10.7
L3
2.2
9.7
2.3
11.6
2.6
11.4
3.1
13.4
(N)
2.2
9.7
2.3
11.6
2.6
11.4
3.1
13.4
single phase
(~230V)
L
L1
6.3
27.5
6.8
29.5
7.5
32.7
8.0
34.7
(N)
L2
6.3
27.5
6.8
29.5
7.5
32.7
8.0
34.7
Table 2. Showing peak power in the different phases for different machine versions.
The machines’ internal electrics consists of 3 heating circuits and an operation circuit. Each circuit is
meant to function on 230Vac. The range in which it can function safely is 208-240Vac. Electric mains
can be connected in two ways to the machine. Check if the electric mains of the location matches the
configuration of the machine.
3-phase machine
What we call a three-phase machine must be connected to 3P-N-E power (3 N
Earth, see Figure 3) with 120 degrees phase shift between phases. Such power is characterised by:
220-240Vac tension between each phase and neutral (or Earth) and 380-400Vac tension between the
phases. For peak power, see Table 2.
Figure 3. 3P-N-E electric mains. Peak current of the Slim Jim is 9.7
– 13.4A per phase.
3N~400V; 3P-N-E
N
L2
L1
L3
E
± 400V
±
0V