F96VTN and G96VTN: Installation, Start-up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
57
Adjust Continuous Fan Airflow (and Low-Speed
Cooling Airflow)
Adjust continuous fan and low-stage cooling airflow using SW2-3, 4, 5
and refer to
. The continuous fan speed can be further adjusted at
a conventional thermostat using the continuous fan speed select
function. Changing the continuous fan speed at a conventional
thermostat DOES NOT change the low-speed cooling airflow selected
via SW2 at the control board.
Refer to the section titled “Continuous Blower Speed Selection for
Thermostat.”
Check Safety Controls
The flame sensor, gas valve, and pressure switch were all checked in the
Start-up procedure section as part of normal operation.
1. Check Main Limit Switch
This control shuts off combustion system and energizes
air-circulating blower motor, if furnace overheats. By using this
method to check limit control, it can be established that limit is
functioning properly and will operate if there is a restricted
return-air supply or motor failure. If limit control does not function
during this test, cause must be determined and corrected.
a. Run furnace for at least 5 minutes.
b. Gradually block off return air with a piece of cardboard or sheet
metal until the limit trips.
c. Unblock return air to permit normal circulation.
d. Burners will re-light when furnace cools down.
2. Check Pressure Switch(es)
This control proves operation of the draft inducer blower.
a. Turn off 115-v power to furnace.
b. Disconnect inducer motor lead wires from wire harness.
c. Turn on 115-v power to furnace.
d. Set thermostat to “call for heat” and wait 1 minute. When
pressure switch is functioning properly, hot surface igniter
should
NOT
glow and control diagnostic light flashes a status
code 3. If hot surface igniter glows when inducer motor is
disconnected, shut down furnace immediately.
e. Determine reason pressure switch did not function properly and
correct condition.
f. Turn off 115-v power to furnace.
g. Reconnect inducer motor wires, replace door, and turn on 115-v
power.
h. Blower will run for 90 sec before beginning the call for heat
again.
i. Furnace should ignite normally.
Checklist
1. Put away tools and instruments. Clean up debris.
2. Verify that switches SW1-1 and SW1-6 are
OFF
and other setup
switches are set as desired. Verify that switches SW1-7 and SW1-8
for the blower
OFF DELAY
are set as desired per
.
3. Verify that blower and control doors are properly installed.
4. Verify that there are no unsealed openings in the blower shelf or
casing.
5. Cycle test furnace with room thermostat.
6. Check operation of accessories per manufacturer’s instructions.
7. Review Owner’s Manual with owner.
8. Attach literature packet to furnace.
Table 20 – Orifice Size and Manifold Pressure (In. W.C.) for Gas
Input Rate
A11252A
- Orifice Size and Manifold Pressure (In. W.C.) for Gas Input
Rate (Continued)
A11252B
S
A
G
L
A
R
U
T
A
N
F
O
Y
T
I
V
A
R
G
C
I
F
I
C
E
P
S
S
A
G
.
G
V
A
HEAT VALUE
0.58
0.60
0.62
0.64
AT ALTITUDE
Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press
(Btu/cu ft)
No.
High/Low
No.
High/Low
No.
High/Low
No.
High/Low
900
43
3.8 / 1.6
42
3.2 / 1.4
42
3.3 / 1.4
42
3.4 / 1.4
0
925
43
3.6 / 1.5
43
3.7 / 1.6
43
3.8 / 1.6
42
3.2 / 1.4
(0)
950
43
3.4 / 1.4
43
3.5 / 1.5
43
3.6 / 1.5
43
3.7 / 1.6
975
44
3.7 / 1.6
44
3.8 / 1.6
43
3.4 / 1.5
43
3.6 / 1.5
to
1000
44
3.5 / 1.5
44
3.6 / 1.5
44
3.8 / 1.6
43
3.4 / 1.4
1025
44
3.3 / 1.4
44
3.5 / 1.5
44
3.6 / 1.5
44
3.7 / 1.6
2000
1050
44
3.2 / 1.3
44
3.3 / 1.4
44
3.4 / 1.4
44
3.5 / 1.5
(610)
1075
45
3.7 / 1.6
45
3.8 / 1.6
44
3.3 / 1.4
44
3.4 / 1.4
1100
46
3.7 / 1.6
46
3.8 / 1.6
45
3.8 / 1.6
44
3.2 / 1.4
U.S.A.
800
42
3.4 / 1.4
42
3.5 / 1.5
42
3.6 / 1.5
42
3.7 / 1.6
2001 (611)
825
43
3.8 / 1.6
42
3.3 / 1.4
42
3.4 / 1.4
42
3.5 / 1.5
to
850
43
3.6 / 1.5
43
3.7 / 1.6
42
3.2 / 1.3
42
3.3 / 1.4
3000 (914)
875
43
3.4 / 1.4
43
3.5 / 1.5
43
3.7 / 1.5
43
3.8 / 1.6
900
44
3.7 / 1.6
44
3.8 / 1.6
43
3.5 / 1.5
43
3.6 / 1.5
Canada
925
44
3.5 / 1.5
44
3.6 / 1.5
44
3.8 / 1.6
43
3.4 / 1.4
2001 (611)
950
44
3.3 / 1.4
44
3.4 / 1.5
44
3.6 / 1.5
44
3.7 / 1.6
to
975
44
3.2 / 1.3
44
3.3 / 1.4
44
3.4 / 1.4
44
3.5 / 1.5
4500 (1372)
1000
46
3.8 / 1.6
45
3.8 / 1.6
44
3.2 / 1.4
44
3.3 / 1.4
775
42
3.3 / 1.4
42
3.4 / 1.4
42
3.5 / 1.5
42
3.6 / 1.5
3001
800
43
3.8 / 1.6
42
3.2 / 1.4
42
3.3 / 1.4
42
3.4 / 1.4
(915)
825
43
3.6 / 1.5
43
3.7 / 1.6
43
3.8 / 1.6
42
3.2 / 1.4
850
44
3.8 / 1.6
43
3.5 / 1.5
43
3.6 / 1.5
43
3.7 / 1.6
875
44
3.6 / 1.5
44
3.7 / 1.6
43
3.4 / 1.4
43
3.5 / 1.5
4000
900
44
3.4 / 1.4
44
3.5 / 1.5
44
3.7 / 1.5
44
3.8 / 1.6
(1219)
925
44
3.2 / 1.4
44
3.4 / 1.4
44
3.5 / 1.5
44
3.6 / 1.5
950
45
3.7 / 1.6
44
3.2 / 1.3
44
3.3 / 1.4
44
3.4 / 1.4
750
42
3.3 / 1.4
42
3.4 / 1.4
42
3.5 / 1.5
42
3.6 / 1.5
4001
775
43
3.7 / 1.6
43
3.8 / 1.6
42
3.3 / 1.4
42
3.4 / 1.4
(1220)
800
43
3.5 / 1.5
43
3.6 / 1.5
43
3.7 / 1.6
43
3.8 / 1.6
825
44
3.8 / 1.6
43
3.4 / 1.4
43
3.5 / 1.5
43
3.6 / 1.5
850
44
3.5 / 1.5
44
3.7 / 1.5
44
3.8 / 1.6
43
3.4 / 1.4
5000
875
44
3.3 / 1.4
44
3.5 / 1.5
44
3.6 / 1.5
44
3.7 / 1.6
(1524)
900
44
3.2 / 1.3
44
3.3 / 1.4
44
3.4 / 1.4
44
3.5 / 1.5
925
46
3.8 / 1.6
45
3.7 / 1.6
44
3.2 / 1.4
44
3.3 / 1.4
725
42
3.2 / 1.4
42
3.3 / 1.4
42
3.4 / 1.5
42
3.5 / 1.5
5001
750
43
3.7 / 1.5
43
3.8 / 1.6
42
3.2 / 1.4
42
3.3 / 1.4
(1525)
775
43
3.4 / 1.4
43
3.5 / 1.5
43
3.7 / 1.5
43
3.8 / 1.6
800
44
3.7 / 1.6
44
3.8 / 1.6
43
3.4 / 1.5
43
3.5 / 1.5
825
44
3.5 / 1.5
44
3.6 / 1.5
44
3.7 / 1.6
44
3.8 / 1.6
6000
850
44
3.3 / 1.4
44
3.4 / 1.4
44
3.5 / 1.5
44
3.6 / 1.5
(1829)
875
45
3.7 / 1.6
44
3.2 / 1.3
44
3.3 / 1.4
44
3.4 / 1.4
900
46
3.7 / 1.6
46
3.8 / 1.6
45
3.8 / 1.6
44
3.2 / 1.4
675
42
3.4 / 1.4
42
3.5 / 1.5
42
3.6 / 1.5
42
3.8 / 1.6
6001
700
42
3.2 / 1.3
42
3.3 / 1.4
42
3.4 / 1.4
42
3.5 / 1.5
(1830)
725
43
3.6 / 1.5
43
3.7 / 1.6
43
3.8 / 1.6
42
3.3 / 1.4
750
43
3.4 / 1.4
43
3.5 / 1.5
43
3.6 / 1.5
43
3.7 / 1.6
775
44
3.6 / 1.5
44
3.7 / 1.6
43
3.4 / 1.4
43
3.5 / 1.5
7000
800
44
3.4 / 1.4
44
3.5 / 1.5
44
3.6 / 1.5
44
3.7 / 1.6
(2133)
825
44
3.2 / 1.3
44
3.3 / 1.4
44
3.4 / 1.4
44
3.5 / 1.5
850
46
3.8 / 1.6
45
3.8 / 1.6
44
3.2 / 1.4
44
3.3 / 1.4
to
to
to
to
TWO-STAGE FURNACE
(TABULATED DATA BASED ON 20,000 BTUH HIGH-HEAT / 13,000 BTUH LOW-HEAT PER BURNER,
DERATED 2%/1000 FT (305M) ABOVE SEA LEVEL)
ALTITUDE
RANGE
U.
S.
A.
On
ly
ft (m)
U
.S
.A
.
an
d
C
an
ad
a
U.
S
.A.
On
ly
U.
S.
A.
On
ly
U.
S.
A.
On
ly
U.
S.
A.
a
n
d
Ca
n
a
d
a
S
A
G
L
A
R
U
T
A
N
F
O
Y
T
I
V
A
R
G
C
I
F
I
C
E
P
S
S
A
G
.
G
V
A
HEAT VALUE
0.58
0.60
0.62
0.64
AT ALTITUDE
Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press Orifice Mnfld Press
(Btu/cu ft)
No.
High/Low
No.
High/Low
No.
High/Low
No.
High/Low
TWO-STAGE FURNACE
(TABULATED DATA BASED ON 20,000 BTUH HIGH-HEAT / 13,000 BTUH LOW-HEAT PER BURNER,
DERATED 2%/1000 FT (305M) ABOVE SEA LEVEL)
ALTITUDE
RANGE
ft (m)
650
42
3.4 / 1.4
42
3.5 / 1.5
42
3.6 / 1.5
42
3.7 / 1.6
7001
675
43
3.8 / 1.6
42
3.2 / 1.4
42
3.3 / 1.4
42
3.4 / 1.5
(2134)
700
43
3.5 / 1.5
43
3.7 / 1.5
43
3.8 / 1.6
42
3.2 / 1.4
725
44
3.8 / 1.6
43
3.4 / 1.4
43
3.5 / 1.5
43
3.6 / 1.5
750
44
3.5 / 1.5
44
3.7 / 1.5
44
3.8 / 1.6
43
3.4 / 1.4
8000
775
44
3.3 / 1.4
44
3.4 / 1.4
44
3.5 / 1.5
44
3.7 / 1.5
(2438)
800
45
3.8 / 1.6
44
3.2 / 1.4
44
3.3 / 1.4
44
3.4 / 1.4
825
46
3.7 / 1.6
46
3.8 / 1.6
45
3.8 / 1.6
44
3.2 / 1.4
625
42
3.4 / 1.4
42
3.5 / 1.5
42
3.6 / 1.5
42
3.7 / 1.6
8001
650
43
3.8 / 1.6
42
3.2 / 1.4
42
3.3 / 1.4
42
3.4 / 1.4
(2439)
675
43
3.5 / 1.5
43
3.6 / 1.5
43
3.7 / 1.6
42
3.2 / 1.3
700
44
3.7 / 1.6
43
3.4 / 1.4
43
3.5 / 1.5
43
3.6 / 1.5
725
44
3.5 / 1.5
44
3.6 / 1.5
44
3.7 / 1.6
44
3.8 / 1.6
9000
750
44
3.3 / 1.4
44
3.4 / 1.4
44
3.5 / 1.5
44
3.6 / 1.5
(2743)
775
45
3.7 / 1.6
44
3.2 / 1.3
44
3.3 / 1.4
44
3.4 / 1.4
9001
600
42
3.3 / 1.4
42
3.4 / 1.5
42
3.6 / 1.5
42
3.7 / 1.6
(2744)
625
43
3.7 / 1.6
42
3.2 / 1.3
42
3.3 / 1.4
42
3.4 / 1.4
650
43
3.5 / 1.5
43
3.6 / 1.5
43
3.7 / 1.6
43
3.8 / 1.6
675
44
3.7 / 1.6
44
3.8 / 1.6
43
3.4 / 1.4
43
3.5 / 1.5
10000
700
44
3.4 / 1.4
44
3.5 / 1.5
44
3.7 / 1.5
44
3.8 / 1.6
(3048)
725
44
3.2 / 1.3
44
3.3 / 1.4
44
3.4 / 1.4
44
3.5 / 1.5