Keeler LOUPES Instructions For Use Manual Download Page 9

 7

EN

KEELER LOUPES

Adjustment

Method

Vertical alignment (height)  

(Fig 4 & 5)

= Pinch or open frame pads

Fig.4

Fig.5

Horizontal alignment (PD)

Fig.6

= Slightly loosen locking knobs 

(interpupillary distance) and slide 

telescope along bar (Fig. 6)

Look through your Loupes at a target that is the correct working distance away. Look through 

first with one eye closed and adjust the alignment until a perfect image appears. Repeat this 

with the other eye. Alternate closing the left and right eye to check binocularity and make 

fine adjustments. Once you are satisfied that you have the best possible image, tighten the 

telescope locking knobs.

Important: 

All Keeler Surgical Loupes are accurately aligned and set for precise binocular 

vision. Under no circumstances should adjustment be made by rotating or holding the 

telescopes, as this may cause the telescopes to misalign and create double vision.
The corrective actions outlined below should be followed for poorly aligned Loupes.

Image 

Quality

Telescope 

Position

Action

Too high

Open frame pads

Too low

Pinch frame pads

Too far left Slide telescope to the right in 

the direction of the shadow

Too far 

right

Slide telescope to the left In 

the direction of the shadow

Adjust the angle and height of your Loupes by adjusting the hinge (Fig. 7).

Fig.7

Summary of Contents for LOUPES

Page 1: ...A world without vision loss Keeler Loupes Magnification Systems INSTRUCTIONS FOR USE...

Page 2: ......

Page 3: ...UST LOUPES FITTED TO A HEADBAND 8 4 2 HOW TO FIT AND REMOVE LOUPES FROM A FRAME OR HEADBAND 8 4 3 HOW TO FIT THE LOUPE FLIP UP LEVER 9 4 4 THE LOUPE HEAD STRAP 10 4 5 FRAME ADJUSTMENTS 10 4 6 PROTECTI...

Page 4: ...eeler Loupes are designed and built in conformity with Directive 93 42 EEC Regulation EU 2017 745 and ISO 13485 Medical Devices Quality Management Systems Classification CE Class I FDA Class II The in...

Page 5: ...re safe operation of the Loupes WARNINGS Please note that the proper and safe functioning of our instruments is only guaranteed if both the instruments and their accessories are exclusively from Keele...

Page 6: ...r Loupes are at the optimal angle to suit you 1 2 CONTRAINDICATION There is no restriction to patient population this device can be used with other than those outlined in the contraindications stated...

Page 7: ...and 1D caps should not be re used if visibly contaminated with uids or blood 6 Manually clean all surfaces of the units using a suitable brush and de ionised water detergent solution 2 detergent by v...

Page 8: ...will comprise of the following additional components Loupe Flip Lever Head Strap Lens cloth Case 4 SETTING UP AND USING YOUR LOUPES The aim in using Keeler Surgical Loupes is to achieve a clear circul...

Page 9: ...satisfied that you have the best possible image tighten the telescope locking knobs Important All Keeler Surgical Loupes are accurately aligned and set for precise binocular vision Under no circumstan...

Page 10: ...by sliding along the bar Fig 6 Note If you are using your Loupes in conjunction with a fiber optic headlamp first adjust the Loupes as described above The light may then be adjusted to illuminate the...

Page 11: ...d on a specially designed hinge permitting the telescopes to be ipped up out of view when not required Fig 10 To avoid touching the non sterile Loupes a sterilisable Loupe Flip Lever is provided with...

Page 12: ...reduce the working distance and are useful if you need to work in two different positions They are also a push fit 5 WARRANTY Your Keeler product is guaranteed for 3 years and will be replaced or repa...

Page 13: ...ps for Hi Res Galilean Loupes pair 2112 P 8065 1D lens cap for Panoramic Loupes pair 2113 P 7001 Protective caps for Panoramic Loupes pair 2113 P 7000 Loupe Flip Lever pack of 7 2199 P 7216 8 OPTICIAN...

Page 14: ...most cases the Bifocal ADD should be the same as the normal prescription However some surgeons prefer the ADD to be of a power that produces a working distance similar to that of the Loupe telescopes...

Page 15: ...act of WEEE Waste Electrical Electronic Equipment and minimise the volume of WEEE entering landfills we encourage at product end of life that this equipment is recycled and reused If you need more inf...

Page 16: ...2021 USA Sales Office Keeler USA 3222 Phoenixville Pike Building 50 Malvern PA 19355 USA Toll Free 1 800 523 5620 Tel 1 610 353 4350 Fax 1 610 353 7814 India Office Keeler India Halma India Pvt Ltd P...

Reviews: