background image

PLEASE READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY

1964-P-

2001

  1964-P-2000

Summary of Contents for 1964-P-2000

Page 1: ...PLEASE READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY 1964 P 2001 1964 P 2000 ...

Page 2: ...ontinued use of a damaged product or part may cause injuries Do not immerse the unit in any liquid Do not use unit if damaged and periodically visually inspect for signs of dam age Keeler cord handles attached to a mains unit provide a 3 6v output to the instru ment head Care must be taken to ensure that only instrument heads fitted with a 3 6V bulb are connected Caution Do not fit into damaged el...

Page 3: ...ower supply to unit and plug in mains fig 1 CHECK fig 2 WALL UNIT DISPENSER TEMPLATE see attached WALL UNIT DISPENSER TEMPLATE Wall Mounting For the Gen Med Unit Dispenser Units drill two holes Ø6mm x 55mm deep and 110mm apart For the Dispenser Unit drill an additional two holes 249mm below the existing holes using template in fig 2 and attached ...

Page 4: ...WALL UNIT DISPENSER TEMPLATE Scale 1 1 Do not scale ...

Page 5: ...fig 3 CAUTION 55mm Ø6mm Ø6mm fig 4 fig 5 ...

Page 6: ...ed see fig 7 To use the required instrument remove the relevant handle from its cradle as shown in fig 8 fig 6 fig 7 Allen Key fig 8 PULL A yellow light LED will illuminate when a cord handle is removed from its cra dle This will occur whether or not an instrument head is fitted When the instrument is no longer required always ensure that the handle is returned correctly to its cradle and that the...

Page 7: ...harge subject to the following 1 Any fault is due to faulty manufacture 2 The power supply has been used in compliance with these instructions 3 Proof of purchase accompanies any claim Technical Information Input data 100 240V 50 60Hz Power Consumption 2 5 Amps Operation Continuous Classification Class II equipment Type B Protection against electric shock Safety Class Double insulated Ambient Temp...

Page 8: ...t non shedding cloth dampened with a water detergent solution 2 by volume or water isopropyl alcohol solution 70 by volume 2 Ensure that excess solution does not enter the instrument Use caution to ensure cloth is not saturated with solution 3 Surfaces should be carefully hand dried using a clean non shedding cloth 4 Safely dispose of used cleaning materials ...

Page 9: ...HONE 0800 521 251 Keeler Instruments Inc 456 Parkway Broomall PA 19008 USA Toll Free 1 800 523 5620 Tel 610 353 4350 Fax 610 353 7814 EP59 48475 Issue A A HALMA GROUP C O M P A N Y DISTRIBUTED BY The CE mark on this product indicates it has been tested to and conforms with the provisions noted within the 93 42 eec Medical Device Directive ...