7.0 

Maintenance 

1.

 

With normal use, a UPS battery will last 3 to 6 years depending on the number of discharges and 
temperature.  

2.

 

Charge the UPS’s battery every 3 months during extended storage. 

3.

 

Disconnect the power during extended storage to avoid overcharge of the battery. 

4.

 

Avoid overload or short circuit although the UPS has built-in overload and short circuit protection 
functions. 

8.0 

Troubleshooting 

Problem 

Possible Cause 

Action 

UPS not On.  LCI not lit 

POWER button not pushed 
or push to short. 

Press the POWER button and 
hold more than 4 seconds. 

PCB failure 

Replace the PCB, call for 
service. 

UPS stays at battery mode 

Power Cord loose. 

Check the power connection. 

AC fuse burned out 

Replace AC fuse 

Line voltage too high, too 
low or black out. 

Normal condition. 

PCB failure 

Replace the PCB, call for 
service. 

Buzzer continuous beeping 

Overload 

Remove the non-critical 
loads 

UPS does not provide 
expected run time. Low 
battery warning is sounded 
prematurely. 

Battery is weak due to wear 
or successive main outages 

Allow UPS to recharge 
battery for a minimum of 8 
hours.  If UPS sounds low 
battery warning prematurely 
when charges and retested, 
then battery should be 
replaced. 

 