Operation Manual ServoOne Supply Unit
34
ID no.: 1101.21B.6-00 Date: 04/2020
4.3.3
Overview of connections, BG5 and BG6a
USB 1.1
ISD00
ISD01
ISD02
OSD02
Relais
ENPO
ENPO
Control
Service
interface
Service
interface
ISDSH
ISA00+
ISA00-
ISA01+
ISA01-
+24V(U
H
)
3
4
5
6
10
15
16
17
9
23
24
22
RSH
12
11
1
2
14
13
ZK−
ZK+
L3
L2
L1
ISD03
ISD04
ISD05
18
19
20
ISD06
21
OSD01
8
OSD00
7
OSD04
DGND
DGND
X
12
X
4
X
10
X
9
X
2
D
1
,
D
2
T
1
,
T
2
Ethernet
X
3
+
−
X
21
L2
L3
N
L1
HREL
–
+
–
+
1
2
1
2
Mains contactor
X
11
DC-link
(BG 6a protected)
24 V DC Supply for
control electronic (U
V
)
DC-link
Top
Bottom
Fr
ont
Option 1
Communication
Fieldbusses
KTY temp. sensor
for set-up reactor
X
5
RB−
RB+
Braking resistor
Mains supply
Mains synchronization
and pre-Charging
24 V bridge only for
SO Supply unit BG5
Danger!
Danger!
Danger!
Figure 4.6 Overview of connections, BG5 and BG6a
No.
Designation
Function
Page
D1, D2
7-segment display
Device state indication
T1, T2
Button
Service functions
Option 1
Communication
Optional module for field bus e.g.
SERCOS, PROFIBUS-DP, EtherCAT or
CANopen
X2
USB 1.1 interface
Service interface, Plug & Play connection
to PC
X3
Ethernet interface
Service interface,
fast TCP/IP connection (RJ45)
X4
Control connections
8 digital inputs, 3 digital outputs,
1 additional relay output
X5
Connection for tempera-
ture monitoring
KTY temperature sensor for step-up choke
X10, X9
Connection for control
supply U
V
Supply voltage for the servocontroller control
electronics, 24 V DC
X11
DC power supply
Connection for DC power supply (BG6a
protected),
PE connection
X12
Power connection
AC mains connection (supply and
regeneration),
PE connection with shield plate,
braking resistor,
(connection for DC power supply, supply
unit BG6a to ServoOne DC axis controller
BG6, 6a)
X21
Connection for mains
synchronisation/
DC link precharging;
auxiliary relay
Mains synchronisation,
DC link precharging, switching on mains
after precharging
SW, HW
Rating plates
Rating plates for software and hardware
Shield connection to
earth
Possible via shield plate (optional)
-
Table 4.1 Key to overview of connections, BG5 and BG6a
Electrical installation
Summary of Contents for ServoOne Series
Page 6: ...Operation Manual ServoOne Supply Unit 6 ID no 1101 21B 6 00 Date 04 2020 Table of contents ...
Page 10: ...Operation Manual ServoOne Supply Unit 10 ID no 1101 21B 6 00 Date 04 2020 ...
Page 90: ...Operation Manual ServoOne Supply Unit 90 ID no 1101 21B 6 00 Date Date 04 2020 Glossary ...
Page 91: ...Operation Manual ServoOne Supply Unit 91 ID no 1101 21B 6 00 Date 04 2020 ...