Operation Manual ServoOne Supply Unit
51
ID no.: 1101.21B.6-00 Date: 04/2020
4.9.1
Specification, control connections
Des.
Term.
Specification
Electrical isolation
Analogue inputs
REL
REL
ISDSH
ISD06
ISD05
ISD04
ISD03
ISD02
ISD01
ISD00
+24V
DGND
RSH
RSH
ENPO
OSD02
OSD01
OSD00
ISA1-
ISA1+
ISA0-
ISA0+
+24V
DGND
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
X4
ISA0+
ISA0-
ISA1+
ISA1-
X4/3
X4/4
X4/5
X4/6
No function
No
Digital inputs
ISD00
ISD01
ISD02
ISD03
ISD04
ISD05
ISDSH
X4/15
X4/16
X4/17
X4/18
X4/19
X4/20
X4/22
•
Frequency range <500 Hz
•
Terminal scan cycle in = 1 ms
•
Switching level low/high: ≤4.8 V / ≥18 V
•
At 24 V typ. 3 mA
Yes
ISD06
X4/21
•
Frequency range ≤500 Hz
•
Switching level low/high: ≤4.8 V / ≥18 V
•
I
max
at 24 V = 10 mA, R
IN
approx. 3 kΩ
•
Internal signal delay < 2 μs suitable as
trigger input for quickly saving the actual
position
Yes
ENPO
X4/10
•
Frequency range <500 Hz
•
Response time approx. 10 ms
•
Switching level low/high: ≤4.8 V / ≥18 V
•
At 24 V typ. 3 mA
Yes
Digital outputs
OSD00
OSD01
OSD02
X4/7
X4/8
X4/9
•
Short circuit proof
•
I
max
= 50 mA, PLC-compatible
•
Terminal scan cycle in = 1 ms
•
High-side driver
Yes
Table 4.10 Specification of the control connections
4.9 Control connections (X4)
1.
Check whether a complete device setup is already available, i.e. whether the drive
has already been configured.
2.
If so, a special control terminal assignment applies.
It is imperative you contact your project engineer to obtain the terminal assignment!
3.
Choose a terminal assignment.
4.
Wire the control terminals using shielded cables.
The following are imperative: 24 VDC to X4/22 and ENPO X4/10 as start signal.
Earth the cable shields over a large area at both ends.
Rigid conductor sizes: 0.2 to 1.5 mm²
Flexible conductor sizes with ferrules: 0.2 to 1.5 mm²
5.
Leave all contacts open
(inputs inactive).
6.
Check all connections again!
Continue with commissioning in chap. 5 on page 59.
Note the following points:
y
Always wire the control terminals with shielded cables.
y
Route mains, motor and signal, DC power supply and braking resistor cables
separated from one another. Maintain a distance of at least 200 mm.
y
A cable type with double copper braiding, with 60...70 % coverage, must be
used for all shielded connections.
Electrical installation
Summary of Contents for ServoOne Series
Page 6: ...Operation Manual ServoOne Supply Unit 6 ID no 1101 21B 6 00 Date 04 2020 Table of contents ...
Page 10: ...Operation Manual ServoOne Supply Unit 10 ID no 1101 21B 6 00 Date 04 2020 ...
Page 90: ...Operation Manual ServoOne Supply Unit 90 ID no 1101 21B 6 00 Date Date 04 2020 Glossary ...
Page 91: ...Operation Manual ServoOne Supply Unit 91 ID no 1101 21B 6 00 Date 04 2020 ...