P30 x-series
Functions
Configuration manual V4.02
30
© KEBA
4.4
UDP interface
The charging station offers the possibility of passing information and receiv-
ing commands via the User Datagram Protocol (UDP). This can be used, for
example, for integration into a SmartHome. For more information, see the
"UDP Programming Guide", which is available in the download area on the
KEBA website.
4.5
Integration of external meters
The charging station can read the measured values from external meters us-
ing Modbus TCP. This allows an intelligent calculation of the charging cur-
rent provided to the vehicle, and the charging process is optimized. The
measured values read are included in the charging current specification. The
following graphic shows the schematic structure of the system.
Illustration 4-7: Modbus TCP system overview
1
... Public power grid
2
... Pre-meter fuse (high-capacity fuse,
line circuit breaker, ...)
3
... Electricity meter of the network op-
erator
4
... Post-meter fuse
5
... External meter (house connection
meter)
Information
The illustration provides an exemplary system overview and does not in-
clude all the necessary ancillary equipment required for safe operation of
the equipment (e.g. line circuit breaker, residual-current device ...).
Summary of Contents for KeContact P30 x-series
Page 1: ...KeContact P30 x series Konfigurationshandbuch Configuration manual ...
Page 2: ......
Page 3: ...KeContact P30 x series Ladestation Konfigurationshandbuch V 4 02 Originalbetriebsanleitung ...
Page 75: ......
Page 76: ...KEBA AG Headquarters Gewerbepark Urfahr 4041 Linz Austria www keba com 98412 ...