This chapter lists all writeable registers that are supported by KeContact
P30.
4.1
5004 - Set charging current
In this register, the charging current can be set in order to control the charg-
ing current. This command directly changes the value permanently and is
valid as long as the device will be rebooted. If the charging current of the
charging station needs to be lowered permanently, a reconfiguration of the
DIP switch settings is recommended (for more information see "Installation
Manual").
Unit: mA
Index
Name
Type
Attr.
5004
Curr User
UINT16
wo
Supported values:
●
6000 − 63000
Example:
Value 8000: The charging current is set to 8000 mA = 8 A.
4.2
5010 - Set energy
In this register, the energy transmission (in 10 watt-hours) for the current or
the next charging session can be set. Once this value is reached, the charg-
ing session is terminated.
Unit: 10 Wh
Index
Name
Type
Attr.
5010
Setenergy
UINT16
wo
Example:
Value 1: The charging session is terminated after an energy transmission of
10 Wh = 0.01 kWh.
4.3
5012 - Unlock plug
In this register, the plug of the charging station can be unlocked. This is only
possible, if the charging station is in suspended state. An ongoing session
can be stopped with register 5014 (disable charging station).