background image

KC-P30

Authorization

Operating instructions V3.26

17

© KEBA

5.2.1

Preparing the charging station

To teach in the RFID master card and to delete the taught-in RFID cards, the
charging station must be rebooted via the service button. To access the ser-
vice button, proceed as follows:

1) Unscrew the two screws on the bottom of the housing
cover 

1

.

2) Lift the housing cover at bottom max. 1 cm 

1

 and then

push upwards 

2

.

3) Unscrew the four screws of the connection panel cover 

1

and remove the connection panel cover upwards.

The service button 

1

 in the connection panel is now acces-

sible.

5.2.2

Teaching in the RFID master card

The RFID master card is the card that is taught in as the first card at the
charging station. It is required for teaching in additional RFID slave cards. In
addition, it can also be used to authorize a charging process.

No charging session may be active for the teaching in and no vehicle may
be connected to the charging station.

Summary of Contents for KeContact KC-P30 Series

Page 1: ...KeContact KC P30 Charging Station Operating instructions V 3 26 Translation of the original instructions...

Page 2: ...due to further technical developments Details presented may be subject to correction All rights reserved KEBA AG Headquarters Gewerbepark Urfahr 4041 Linz Austria Phone 43 732 7090 0 Fax 43 732 7309...

Page 3: ...umentation 6 2 Safety notes 7 3 Description of the charging station 9 3 1 Front view 9 3 2 Type plate 10 3 3 Overview of variants 10 3 4 Options 12 4 Displays and operating elements 13 4 1 LED bar 13...

Page 4: ...th or se rious bodily injury if the corresponding precautions are not taken WARNING indicates a potentially hazardous situation which can result in death or seri ous bodily injury if the corresponding...

Page 5: ...intended use are observed the product will normally not pose a risk to the health of persons or damage to property Not observing the safety instructions can result in risk of death in juries and dama...

Page 6: ...ing behavior of the charging station Operation of the charging station 1 6 2 Not contained in this document Assembly disassembly of the charging station Commissioning of the charging station Troublesh...

Page 7: ...ectrician A repair of the charging station is not permitted and may only be carried out by the manufacturer No unauthorized conversions and modifications may be made to the charging station No marking...

Page 8: ...ot by the cable The charging cable may not be not damaged mechanically kinked pinched or driven over and the contact area is not allowed to come into contact with sources of heat dirt or water Never c...

Page 9: ...tion 1 Housing cover 2a RFID reader optional 2b Key operated switch optional 3 LED bar 4a Permanently installed charging ca ble optional 4b Charging socket with cover op tional 5 Holder for charging c...

Page 10: ...ct designation 5 Technical data 6 Marking of the approval 7 Type examination number 8 Accuracy class in accordance with EN 50470 1 3 9 CE marking 10 Public key information 11 Production site 12 Produc...

Page 11: ...ries 2 x series WLAN B x series GSM G x series WLAN GSM C Switching element x 1 phase contactor 1 3 phase contactor 2 Energy meter x None 0 Energy meter not calibrated E Calibratable energy meter MID1...

Page 12: ...he RFID reader is used for the non contact authorization of a charging process with MIFARE cards or tags according to ISO 14443 and ISO 15693 Fig 3 3 RFID 1 RFID reader 3 4 2 Key switch The key switch...

Page 13: ...en after plugging in Locking of the charging cable to the charging socket Green The plugged in charging cable is locked and charging can be started by the vehicle Flashing green every second Execution...

Page 14: ...and switched off after a few minutes The display lights up through the housing and is only visible when the power supply is active 4 2 1 Display with energy meter The following information is shown on...

Page 15: ...r repair National approval Calibratable energy meters with national approval also feature the following displays Display Description Transmitted energy of the current charging process Display during a...

Page 16: ...seconds Authorization done correctly No authorization required Flashing blue every 3 seconds The charging station is waiting for authorization to enable a charging process Authorization necessary eit...

Page 17: ...om max 1 cm 1 and then push upwards 2 3 Unscrew the four screws of the connection panel cover 1 and remove the connection panel cover upwards The service button 1 in the connection panel is now acces...

Page 18: ...nds and a charging session authorized by the RFID master card can be started After this the LED bar flashes blue to indicate that au thorization to start a charge is required 5 2 3 Teaching in the sla...

Page 19: ...aught in cards in the process If the deletion was successful the LED bar flashes green and charging with out authorization is possible 5 2 5 RFID authorization at charging network If the charging stat...

Page 20: ...card or plugging in and turning the key to the right The key can then be removed The charging process can now be started by the vehicle If an interruption occurs during the plugging in or charging pro...

Page 21: ...down the charging process is continued and the charging current may be increased again Protect the vehicle and the charging station from direct sunlight during the charging process carport garage etc...

Page 22: ...must be checked regularly by the owner for faulty sockets and charging connector including the charging cable and damage to the housing visual inspection Use a soft damp cloth for cleaning Stubborn d...