KC-P30
Displays and operating elements
Operating instructions V3.26
13
© KEBA
4
Displays and operating elements
4.1
LED bar
Fig. 4-5: Segments of the LED bar
The LED bar provides visual information about the current operating status
of the charging station. It consists of 4 segments (
S1
to
S4
), which can light
up or flash, together or individually, in various colors.
The LED bar is only visible with activated power supply.
Display
Description
Dark
No power supply or defect, for details see "Diagnosis"
Flashing green
(every 3 seconds)
Ready for operation
or with authorization option: Authorization done correctly
Flashing blue
(every 3 seconds)
The charging station is waiting for authorization to enable a
charging process.
Flashing green
(after plugging in)
Locking of the charging cable to the charging socket
Green
The plugged-in charging cable is locked and charging can be
started by the vehicle.
Flashing green
(every second)
Execution of a charging process (applies to “EN 61851 Mode 3“
charging process)
Flashing green
(every 3 seconds)
Charging complete and charging socket unlocked. The charging
cable can be unplugged.
Flashing orange
(every 5 seconds)
If the charging station is out of service, for example in the event
that the temperature is exceeded, the charging process is tem-
porarily interrupted and resumed after cooling down.
Blue and orange
The charging station is in start-up.
Orange
(5 seconds)
Self-test during start-up
Orange
(S2)
The charging station is in commissioning mode.
Flashing red
Error, for details see "Diagnosis"
Blue/red
Red/white
Error display via color code, for details on possible causes of er-
ror and troubleshooting see "FAQs" on our website