Maintenance
The device is inherently maintenance free.
11.1
Software update via web server
A software update can be performed using the web server integrated in the
device. For this purpose, a PC with the saved update file ("su100.up") in the
same network is required.
To perform the software update, proceed as follows:
1) Press and hold the reset button using a pointed object for approx. 15
seconds or use the Modbus TCP protocol to write the value
0xA0B1
to
the bootloader register. The status LED flashes green.
2) Open the web server by entering the IP address of the device in a web
browser on the PC. The device must be in bootloader mode to do so.
3) Select the update file using "Select file."
4) Press "Upload." The "Update in Progress" message appears in the dia-
log window and the status LED flashes orange.
If the update is successful, the "Update successful" message appears in the
dialog window. The device restarts automatically and the web browser can
now be closed.
The software update has now been performed.
11.2
Troubleshooting
Error
Possible causes
Remedy
Status LED does
not light up.
No supply voltage.
●
Ensure that at least the phase
conductor L1 and neutral con-
ductor N are connected.
Summary of Contents for KeContact E10
Page 1: ...KeContact E10 Energy meter Installation manual V 1 00 Original instructions...
Page 30: ...E10 Declaration of conformity V1 00 30 KEBA 2023 15 Declaration of conformity...
Page 31: ...E10 Declaration of conformity V1 00 31 KEBA 2023...
Page 33: ......
Page 34: ...KEBA Energy Automation GmbH Reindlstra e 51 4040 Linz Austria www keba com...