D3-DA 3xx/x
Appendix: Further components
Project engineering manual V1.07
115
© KEBA
Signal
Connector S1
(Motor-sided)
Color of wires /
identification
Connector S2
(Drive control
system-sided)
W
4
Black, white figure 3
W
Temp +
A
Black, white figure 5
1
Temp -
B
Black, white figure 6
2
Br +
C
Black, white figure 7
3
Br -
D
Black, white figure 8
4
16.3.2
Connection cable XW H0x-xxx
Information
The cables are also used for signal connection of Hiperface DSL encoder
and are only intended for a direct connection from the axis module to the
motor. If intermediate sockets are required, ensure that a continuous
shielding of the Hiperface DSL elements from the axis module to the motor
is retained. The existing M23 connector may need to be replaced by an-
other suitable connector.
Fig. 16-56: Structure of the connection cable XW H0x-xxx
S1
... Connector motor-sided
S2
... Connector axis module-sided
1
... Outer and inner shields connected
to copper strip
2
... Shrinking tube overlaps the copper
strip (5 mm)
3
... Shield is fixed at the mounting plate
4
... Cable of length L
PE
... Not connected
Pin assignment at connection cable XW H0x-xxx
Signal
Connector S1
(Motor-sided)
Color of wires /
identification
Connector S2
(Axis module-
sided)
U
1
Black, white imprint U U
PE
2
Green-yellow
n.c.