4-6
Operating Instructions CDF3000
4 Commissioning
4.3
Initial commis-
sioning
Prerequisites:
• The positioning controller is completely connected, see Chapter 3
• Installed D
RIVE
M
ANAGER
from version V3.4
• The database for motors is installed on the notebook
• The unit is connected to the notebook via the RS232 interface (X4)
Attention:
Never wire or disconnect electrical connections while they are
live.
Input ENPO = apply Low-Level to terminal X2/12 to avoid unintended
starting of the motor (output stage locked, mains voltage for positioning
controller switched on).
Preparations:
• Switching on the positioning controller CDF3000.
A self-test is performed.
• Start the D
RIVE
M
ANAGER
.
Set up a connection to the device.
D
RIVE
M
ANAGER
Connect
or:
Communication > Connect...