Page 3.5 - 4
COMBIVERT R6-N
© KEB, 2015-07
Regenerative adjustments
3.5.3 Deactivate regeneration
If the active power exceeds the level specified in cS.06 the modulation is switched off after puls off delay
(cS.05).
Parameter
Addr.
R PG E
Min.
value
Max.
value
Res. [?] Default
cS.05 puls off delay
0F05h rw
-
-
0
32000
1
ms
200
Parameter
Addr.
R PG E
Min.
value
Max.
value
Res. [?] Default
cS.06 puls off level
0F06h rw
-
-
-10000
0
1
kW
-0.8
3.5.4 Optimization for regeneration
Parameter
Addr.
R PG E
Min.
value
Max.
value
Res. [?] Default
cS.04 switch off delay OSF
rw np E
-10
+10
1
–
0
Offset of the modulation window at the start of the modulation with harmonic filter
Parameter
Addr.
R PG E
Min.
value
Max.
value
Res. [?] Default
cS.07
mains sync. filter quality
0F07h rw np E
1
8
1
–
1
The smaller the value, the faster the internal mains synchronisation follows the main voltage frequency fluc
-
tuations.
Parameter
Addr.
R PG E
Min.
value
Max.
value
Res. [?] Default
cS.08 Kp - comm.choke
0F08h rw np E
7
13
1
–
10
Gain of the controlled variable at commutation choke.
Parameter
Addr.
R PG E
Min.
value
Max.
value
Res. [?] Default
cS.09 Ki - comm.choke
0F09h rw np E
5
11
1
–
8
Controller speed at commutation choke.
Parameter
Addr.
R PG E
Min.
value
Max.
value
Res. [?] Default
cS.11
Kp - harm.filter
0F0Bh rw np E
7
13
1
–
10
Gain of the controlled variable at harmonic filter.
Parameter
Addr.
R PG E
Min.
value
Max.
value
Res. [?] Default
cS.12
Ki - harm.filter
0F0Ch rw np E
5
11
1
–
8
Controller speed at harmonic filter.
Summary of Contents for COMBIVERT R6-N
Page 2: ...Page1 1 2 COMBIVERT R6 N KEB 2015 07 Introduction ...
Page 4: ...Page1 1 4 COMBIVERT R6 N KEB 2015 07 Introduction ...
Page 14: ...Page1 2 6 COMBIVERT R6 N KEB 2015 07 Product overview ...
Page 28: ...Page2 1 6 COMBIVERT R6 N KEB 2015 07 Fundamentals ...
Page 34: ...Page2 2 6 COMBIVERT R6 N KEB 2015 07 Password input ...
Page 40: ...Page3 1 2 COMBIVERT R6 N KEB 2015 07 Parameter summary 3 1 1 Parameter list R6 N 3 1 3 ...
Page 128: ...Page 3 9 10 COMBIVERT R6 N KEB 2015 07 Define CP Parameters ...
Page 136: ...Page 4 1 8 COMBIVERT R6 N KEB 2015 07 Preparatory measures ...
Page 146: ...Page 5 1 6 COMBIVERT R6 N KEB 2015 07 Error Diagnosis ...
Page 156: ...Page 7 1 2 COMBIVERT R6 N KEB 2015 07 Appendix 7 1 1 Index 7 1 3 ...