GB-5
Inputs / Outputs
1.2
Terminal X3 I/O-Expander (units > G-housing)
Terminal
Function
1
Digital input signal: contactor control (see chapter 3.6)
max. voltage endurance to ground: 100 V
2
Setpoint input correction-speed: V
B
digital inputs for setpoint activation
3
Setpoint input positioning speed: V
E
! only valid with LF.2 = 2 !
4
Setpoint input rated speed: V
N
max. voltage endurance to ground: 100 V
5
Setpoint input inspection speed: V
I
6
Setpoint input intermediate speed 1: V
1
terminal assignment with binary coded
7
Setpoint input intermediate speed 2: V
2
set value selection see LF.2
8
Option ! do not connect !
9
+ 24 ... + 30 V external voltage input
External supply voltage
10
for relay outputs on terminal X3
11
Ground for X3.9 / X3.10
12
13
Output signal: ready / overspeed
≈
U
X3.9 / X3.10
/ 500 mA
see chapter 3.4
14
Output signal: switching frequency warning
≈
U
X3.9 / X3.10
/ 500 mA
see chapter 3.4
15
Output relay contact: braking control
30 V DC / 1 A
see chapter 3.4
16
17
Output signal: delay control
≈
U
X3.9 / X3.10
/ 500 mA
see chapter 3.4
18
Output relay contact: running open doors
30 V DC / 1 A
see chapter 3.4
19
20
Output relay contact: main contactor control
30 V DC / 1 A
see chapter 3.4
21
22
Output signal: DC monitoring
≈
U
X3.9 / X3.10
/ 500 mA
see chapter 3.4
23
Output signal: motor temperature warning
≈
U
X3.9 / X3.10
/ 500 mA
see chapter 3.4
Summary of Contents for COMBIVERT F4-F