Installation
©
2021 KEB America, Inc.
27
Figure 7 Air Gap
Size
02
03
04
05
06
07
08
09
10
11
Xn [mm]
0.2
0.2
0.2
0.2
0.3
0.3
0.4
0.4
0.5
0.6
9.
Connect the COMBISTOP brake lead lines to an appropriate DC voltage to test brake
function. The brake will release when voltage is applied, and engage when the voltage
supply is powered off.
10. The COMBISTOP brake is now ready for use.
Refer to the following chapter for instructions on installing optional components.