5 Assembly
5.1 Assembly instructions
To prevent damage to the product, the following instructions must be observed:
• Make sure that no components are bent and/or insulation distances are changed.
• In case of mechanical defects, the product must not be put into operation. Compliance
with applied standards is no longer guaranteed.
• No moisture or mist may penetrate the product.
• The penetration of dust must be avoided. When installing in a dust-tight housing, en-
sure sufficient heat dissipation.
• (≡►
Minimum installation distances of the filter [
) to surrounding elements.
• Do not cover ventilation openings.
• Install the product in accordance with the specified construction and protection degree.
• Make sure that no small parts (drilling chips, screws, etc.) fall into the product during
assembly and wiring. This also applies to mechanical components, which can lose
small parts during operation.
During assembly <link linkid="341440780" use="grab">Mechanische Umweltbedingun-
gen</link> are only observed under the following conditions:
• Use fixing material with the described quality.
• Observe tightening torques
5.1.1 EMC notes on assembly
90% of the interferences caused by EMC can be prevented by the following measures:
a) The contact surface of the filter on the mounting plate must be electrically conductive.
b) The contact surface between the drive controller and the filter must be free of impurit-
ies in order to have a low-resistance, large-area transition here as well.
c) Use the optionally available shield connection bracket.
d) The motor shield must be placed over a large area on the shield connection bracket
of the drive controller.
ð
Electromagnetic interference can now be dissipated over a large area via the mass.
Electromagnetic compatibility:
(►
https://www.keb.de/fileadmin/media/Techinfo/dr/tn/
5.2 Mounting the filter
• Prepare drill holes
• Screw the filter onto the mounting plate with the specified torque.
• Connect the filter.
• Tighten the screws with the specified torque.
5.3 Mounting direction
a) Mount the device only in the permitted mounting orientation.