OPEraTING SySTEMS
4 Operating Systems
4.1 KEB Windows Images (Windows Embedded Standard 7 / Windows 10)
4.1.1 Introduction
KEB has created a “Windows Embedded Standard 7" (WES7) / Windows 10 (Win10)
image for C6 E22 / C6 P3x with special features that support the work with the devices.
4.1.2 User accounts
There are two user accounts implemented in the KEB image: AutoLogon and remote.
The following table shows the details for the accounts:
account
autoLogon
remote
administrator
Yes
Yes
Password
No
remote
remote access
Not possible
Yes
Intention
Automatic logon after reboot
Remote Desktop connection
Table 7:
User Accounts
WarNING
The default password for “remote” account should be changed to
an individual password for security reasons.
The AutoLogon should be continuously used as the standard logon, because only a
logon without password reaches immediate start of Control and HMI application after
boot of the device, which is generally the desired behavior for a machine control device.
Since in WES7 / Win10 a remote logon as account without password is not possible,
there is no security risk regarding the missing password for AutoLogon.
Of course own user accounts can be created, but this is not the default approach des-
tined by KEB.
4.1.3 Ethernet address
The C6 E22 / C6 P3x are configured to obtain an IP address from a DHCP server. If no
DHCP server is available in the network the device uses the IP address 192.168.0.100.
Thus it is also possible to connect directly to the device without a network infrastructure
with a development PC by configuring the Ethernet adapter of the development PC with
another 192.168.0.xxx address.
Switching to the IP address 192.168.0.100 by the device can take several
minutes because the device waits this time for the possible DHCP address
assignment.