background image

     

keatingofchicago.com

CLEANING THE UTENSILS

Spatulas

 should be hand washed 

in mild to medium strength deter-
gent and towel dried. 

NOTE:

 Avoid contact with Chlorine 

or bleach, it will discolor the 
steel spatula. Rubbing the spat-
ula with vegetable oil will slow 
discoloration.

Rinse 

scraper

 and carefully 

wipe blade with a dry cloth. 
Cover blade with plastic protec-
tion cover when not in use.

Rinse Palmetto brush until 
clean.

NOTE: BECAUSE OF THE SUPERIOR MIRACLEAN® 
SURFACE, THE ONLY TOOLS YOU WILL EVER NEED 
TO CLEAN THE GRIDDLE ARE A NATURAL BRISTLE 
BRUSH AND A KEATING SCRAPER.

 

 

NEVER USE A GRIDDLE STONE, BRICK OR SCREEN 

TO CLEAN THE MIRACLEAN® SURFACE.

  

 

DAMAGE DONE TO THE MIRACLEAN® SURFACE BY 

GRIDDLE STONE, BRICK OR SCREEN WILL VOID THE 
WARRANTY.

 

 

THE DAMAGE DONE TO THE MIRACLEAN® SURFACE 

IS IRREPARABLE.

 

NEVER USE ICE TO COOL THE MIRACLEAN® 

SURFACE. USE OF ICE MAY WARP THE MIRACLEAN® 
PLATE.

 

 

USE ONLY KEATING SUPPLIED CLEANING TOOLS 

AND KLENZER.

 

USE ONLY KEATING SPATULAS.

 

DO NOT WASH STEEL SPATULA WITH CHLORINE OR 

BLEACH AS IT WILL DISCOLOR.

NOTE: 

Keating Klenzer MSDS is available on our 

website.

SHUTDOWN

1. For 208 - 240 Volt Unit: Turn each thermostat fully 
counterclockwise and On/Off switch to “OFF” position.

For 480 Volt Unit: Turn thermostat knob to “OFF” 
position.

MAINTENANCE

WARRANTY REPAIRS

Keating’s warranty begins with the date of installation. 
In the event that your MIRACLEAN® Electric Griddle, 
under warranty, needs repairs other than routine 
maintenance or cleaning, you are required to contact 
Keating of Chicago (at 1-800-KEATING) before calling a 
local service company.

PREVENTIVE MAINTENANCE

Preventive maintenance should be done in daily, week-
ly, monthly and yearly intervals as necessary. Following 
preventive maintenance procedures will help keep your 
MIRACLEAN® working effi ciently. Proper care and servic-
ing will lead to years of quality performance.

TIME FRAME

OPERATOR/OWNER

AT LEAST 

DAILY*

• Check lights and controls.

• Clean griddle surface.

• Drain and clean grease drawer.

• Completely wipe down griddle
   cabinet.

AT LEAST 

MONTHLY*

• Check condition of Miraclean® 
   surface and review proper 
   cooking procedures.

• Check calibration of 
   thermostat(s).

• Review operating instructions
   received with Miraclean® griddle.

TIME FRAME

QUALIFIED SERVICE PERSONNEL

AT LEAST 

YEARLY*

• Have Miraclean® Griddle 
   completely checked, calibrated, 
   tested, cleaned, etc. by qualifi ed 
   service personnel.

*

High production facilities should be checked more often.

Contact the factory or a local service company to perform 

maintenance and repairs.

A. Griddle Surface

With proper care, the MIRACLEAN® surface and its 
unique cooking properties will last for many years. 
However, nicks or dents in the griddle surface may 
cause the griddle surface to lift from the depressed 
area. If nicks are close together, the surface may raise 
and be torn when a spatula or scraper is used. Care 
should be taken, as the damage done is irreparable. 
See Figure 3-3. 

6

HAMBURGER 
SPATULA

GRIDDLE
SCRAPER

Summary of Contents for pre 2000 series

Page 1: ...formed it is in your interest to obtain and keep all receipts Keating commercial griddles are not intended for household use As continuous product improvement occurs specifications may be changed with...

Page 2: ...r appliance 9902091 9902091 i Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions...

Page 3: ...service personnel Operating information for Keating equipment has been prepared for use by qualified and or authorized personnel Keating equipment is made in the USA and has American sizes of hardware...

Page 4: ...ment will void the warranty Before uncrating check equipment carefully for damage INSTALLATION Installation must conform with local codes or in absence of local codes with the current National Electri...

Page 5: ...riddle terminal connections to the appropriate wiring diagram for the griddle see pages 12 14 Wiring Diagram to see if the griddle is connected three phase or single phase All wires cords plugs recept...

Page 6: ...ing MIRACLEAN Griddles are designed to provide maximum production efficiency and deliver high quality food products Follow cooking procedures below 1 For 208 240 Volt Unit Set ON OFF switch to ON posi...

Page 7: ...EAN GRIDDLE The surface of the MIRACLEAN Griddle is very durable and with proper care following the procedures below will last many years A sample of Keating Klenzer Keating palmetto brush and a 4 scr...

Page 8: ...r MIRACLEAN Electric Griddle under warranty needs repairs other than routine maintenance or cleaning you are required to contact Keating of Chicago at 1 800 KEATING before calling a local service comp...

Page 9: ...g screws See Figure 4 1 rotate dial plate to match thermometer reading and tighten screws NOTE Calibration is not covered under warranty CLEANING Proper care should be taken to fully clean the griddle...

Page 10: ...is faulty a Replace indicating light Temperature of griddle is erratic a Thermostat out of calibration b Thermostat bulb improperly placed c Exhaust problems or drafts in kitchen a Calibrate thermost...

Page 11: ...E DRAIN 24 DEEP GRIDDLES N A 30 AND 33 DEEP GRIDDLES 002446 32 MODEL A GRIDDLE 002457 4 UPPER HEAT SHIELD CALL 1 800 KEATING 5 PLATE AND PERIMETER CALL 1 800 KEATING 6 TERMINAL BLOCK 27 36 WIDE GRIDDL...

Page 12: ...LATE 250 400 F 034870 THERMOSTAT DIAL PLATE 150 500 F 012018 3 THERMOSTAT 150 550 F 208 240 VOLT 029521 THERMOSTAT REPLACEMENT KIT 400 F 035954 4 ON OFF SWITCH 2 POLE 30 AMP HEAVY DUTY 007246 5 CONTRO...

Page 13: ...1 4 HEATING ELEMENT PAN 020553 1 020554 1 020556 1 5 HEATING ELEMENT BULB HOLD DOWN M BRACKET 008593 1 1 1 6 HEATING ELEMENT HOLD DOWN BRACKET 029352 3 4 5 7 3 8 NUT WASHER LOCK WASHER AND PALNUT 028...

Page 14: ...AGRAM NOTE Griddles rated at 480 volts use type D 1 thermostats which include On Off switches Separate On Off switches are not provided with these griddles The following wiring diagrams are for griddl...

Page 15: ...1 800 KEATING ELECTRIC GRIDDLE SERIES PRE 2000 13 36 WIDE ELECTRIC GRIDDLE WIRING DIAGRAM 42 48 WIDE ELECTRIC GRIDDLE WIRING DIAGRAM...

Page 16: ...keatingofchicago com 14 60 WIDE ELECTRIC GRIDDLE WIRING DIAGRAM 72 WIDE ELECTRIC GRIDDLE WIRING DIAGRAM...

Page 17: ...NTS 2300W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 6 2 17 17 17 30 220 6 9 18 18 18 31 240 8 2 20 20 20 34 36x24 3 ELEMENTS 2300W EACH VOLTS kW AMPS PER LINE THREE PHASE...

Page 18: ...4 24 24 41 240 10 7 26 26 26 45 36x30 3 ELEMENTS 3000W EACH VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 10 7 34 34 22 51 220 12 0 36 36 24 55 240 14 3 39 39 26 60 42x30 48x30 4 E...

Page 19: ...MENTS 3750W EACH 17 MODELS STANDARD AND FRONT TROUGH ONLY VOLTS kW AMPS PER LINE THREE PHASE L1 L2 L3 AMPS SINGLE PHASE 208 10 1 28 28 28 49 220 11 3 30 30 30 51 240 13 4 32 32 32 56 36 DEEP MODELS 36...

Page 20: ......

Page 21: ......

Page 22: ...RANTY CARD ON OUR WEBSITE FOR YOUR CONVENIENCE COMPANY ADDRESS CITY STATE ZIP CODE DEALER NAME DATE OF PURCHASE INVOICE SERIAL MODEL I HAVE READ THE INSTALLATION AND OPERATING INSTRUCTIONS SIGNED DATE...

Reviews: