background image

A. FILTER-DRAWER

WARNING!

WATER + HOT OIL = DON'T MIX!

1. Operator should be outfitted with proper protective

attire: safety goggles, oil and heat resistant gloves,
apron and footwear

2. Release intake hose from filter drawer using the quick

disconnect. Refer to Figure 1.

3. Pull filter drawer forward and remove the cover and

strainer basket.  Refer to Figure 2.

4. Release the spring loaded T-Arms located in the corners

of the filter drawer and remove the hold down ring. Refer
to Figure 2. 

5. Filter screen should be in bottom of drawer. Place filter

paper on top of screen.

6. Position hold down ring on top of paper and secure with

T-Arms. Refer to Figure 3.

NOTE:

Hold down ring makes a gasket-like seal on filter

paper. Filter paper must be placed edge to edge from front to
back, overlapping on sides. Filter Paper must be smooth and
flat under hold down ring to get a proper seal.

NOTE:

One package of Acidox is needed for every 40 pounds

of oil.

7. Sprinkle Keating Acidox Powder evenly over the paper.

8. Replace strainer basket and cover, push drawer fully into

cabinet and reconnect intake hose and pull up on hose to
check connection. 

CAUTION

Pull up on hose to check connection.

NOTE:

Cabinet door should be closed during filtration.

NOTE:

For best results, new filter paper and Acidox Powder

should be used for each fryer.

B.

PREPARING OIL FOR FILTRATION

NOTE:

Oil in fryer must be between 250° - 350°F.

1. Turn fryer completely off.

FIGURE 2.  FILTER DRAWER ASSEMBLY

FIGURE 3.  FILTER DRAWER COMPLETE WITH
SCREEN, FILTER PAPER, HOLD DOWN RING,
ACIDOX, STRAINER BASKET AND COVER.

HANDS FREE

CENTRAL FILTER

OPERATING INSTRUCTIONS

KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL

FIGURE 1.  QUICK DISCONNECT

– 1 –

Summary of Contents for Central Filter Hands Free

Page 1: ...edge to edge from front to back overlapping on sides Filter Paper must be smooth and flat under hold down ring to get a proper seal NOTE One package of Acidox is needed for every 40 pounds of oil 7 Sp...

Page 2: ...t pump switch to MELT position for ten minutes to melt any solidified shortening in the return pipe only on models with melt cycle 5 Let the pump run with drain valve open to remove crumbs and residue...

Page 3: ...strainer basket and cover push drawer fully into cabinet and reconnect intake hose Check to ensure proper connection 10 Close the cabinet door NOTE Instructions for cleaning the fryer are in the Opera...

Page 4: ...er brush may be used to scrub the tubes elements and inside walls of fryer Pump the water and Sea Powder into a dry suitable receptacle and remove from cooking area Sprinkle Keating Klenzer liberally...

Page 5: ...for CF24 Filter Drawer not shown 023206 Caster for Cradle without brake not shown 020866 Caster for Cradle with brake not shown 012160 10 Intake Hose 000652 Intake Hose with Quick Disconnect 020023 11...

Page 6: ...ions are tight and hoses filter vessel are not cracked and leaking Tighten connections or replace defective hoses 2 Filter paper totally clogged 2 Replace filter paper and apply Acidox Powder being su...

Page 7: ...Tel 708 246 3000 Fax 708 246 3100 Toll Free 1 800 KEATING www keatingofchicago com If you have any questions regarding filtering procedures or need assistance call 1 800 KEATING Central Filter pre2000...

Page 8: ...SE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from improper installa...

Page 9: ...___________________________________________________________ INVOICE NUMBER ____________________________ SERIAL NUMBER ________________________________________ FRYER FILTER SYSTEM GRIDDLE REMARKS _____...

Reviews: