background image

10×11 COUNTER MODEL GAS

As continuous product improvement occurs, specifications may be changed without notice.

Oil

BTU

Working

Overall

Ship

Model No. and Description

Capacity

Input

Height*

Height

Depth

Width

Wt.

10×11 CMG Nat Gas

26 lbs.

54,000

19

3

/

8

"

27

3

/

8

"

25

1

/

4

"

12

3

/

8

"

110 lbs.

10×11 CMG LP Gas

26 lbs.

50,000

19

3

/

8

"

27

3

/

8

"

25

1

/

4

"

12

3

/

8

"

110 lbs.

from the bottom of the fryer to the panel, and above the
panel shall be a canopy. The door shall be the full width of
the cabinet. No additional space is required for the door to
open a full 90 degrees. A stainless steel flue deflector is to
be provided for installing onto the flue back.

Heat Transfer Tubes

to be two, made of stainless steel

polished to a #7 mirror finish. 

Thermostat

shall be close range, hydraulic type and be

accurate to ±3°F from 300° to 350°F with stainless steel
bulb. Application of this thermostat is patented by Keating.

Hi-Limit Control

shall be manually resettable type with

stainless steel bulb.

100% Safety Shut Off

shall be millivolt type with dual

combination control gas valve and thermopile.

Standard Accessories

to include one pair 4 mesh baskets,

grid screen over heat transfer tubes, drain clean out rod,
1"×11 

1

/

2

" drain extension and sample of Keating Klenzer

and Sea Powder.

Electrical Requirements

are not necessary on AA models.

Gas Requirements

to install are 

3

/

4

" male NPT connection

and 4" water column pressures natural and 10" for LP gas at
the fryer burner manifold. Supply pressure to fryers must be
7" (natural gas) and 11" (LP) water column.

Special Order Options

may include cover, full size

baskets, thermostat seals, portable filter, security package.

*Denotes height from top of counter to top of fryer deck.

COUNTER MODEL INST

ANT RECO

VER

Y

®

FR

YER

10×11 CMG GAS

Printed in U.S.A.

10x11cmg2006

12/06

KEATING OF CHICAGO, INC.

Toll Free 1-800-KEATING

www.keatingofchicago.com

12

DESCRIPTION

The Keating Instant Recovery

®

Counter Model Fryer consists

of a frying vessel 10×11” having a splash deck and a splash
back installed in a cabinet equipped with gas burners and an
automatic temperature control mechanism, all arranged and
designed for the proper frying of food.

SPECIFICATIONS
Frying Vessel: 

shall be constructed from 18 gauge

stainless steel, shall have a shortening capacity of 26
pounds, shall be equipped with two 18 gauge horizontal
heat transfer tubes spaced above the bottom of the vessel
so that the bottom is unheated and the food particles
collecting in this bottom zone are unheated and therefore
do not carbonize. The frying vessel shall be polished to
inhibit carbon build-up and facilitate easy clean-up. 

The

heat transfer tubes shall be 3" wide and 5" high. The bottom
of the vessel shall slope toward the front where it shall be
equipped with a 1" Teflon core 

1

/

4

turn, drain valve, so

arranged that the shortening can be drained into a receiving
vessel placed in front of the fryer.

Splashdeck

shall slope toward the shortening containing

vessel. 

The splash deck shall be made of 16 gauge 304

stainless steel.

Splashback 

shall be made of 18 gauge 304 stainless steel,

shall completely cover the sides of the flue.

Cabinet: 

shall be made of 18 gauge stainless steel. The

cabinet shall be rigid in construction and shall have four
4" adjustable legs. A door made of 22 gauge 304 stainless
steel 

shall cover the front of the cabinet and shall extend

Reviews: