Parameters:
MANUAL CONTROL
MANUAL VALVE
CLEAR ALARMS
MANUAL COMPRESSOR RELAY
MANUAL DEFROST RELAY
MANUAL FAN RELAY
DHCP
FACTORY RESET
Menus:
Variables
Manual
(view only)
Non-adjustable
NO ALARM
PRESSURE SENSOR
SUCTION TEMP SENSOR
AIR TEMP SENSOR
COIL TEMP SENSOR
AUX TEMP SENSOR
HIGH SUPERHEAT
LOW SUPERHEAT
HIGH AIR TEMP
LOW AIR TEMP
EXCESS DEFROST
DEFR TERM ON TIME
DOOR SWITCH
COMMUNICATION ERROR
EXT ALARM
Alarms
(view only)
ENTER
ENTER
Left Arrow and Right Arrow
Use to move between Menus
Up Arrow and Down Arrow
Scroll through Menu Parameters
ENTER
Press and hold ENTER for 3 seconds, when display
begins blinking changes can be made
BACK
Press BACK to return to the previous view
ENTER
Press and hold ENTER for 3 seconds to save change
To change settings:
To save setting changes:
To move through
controller menus:
To return to Main Menu:
Indicator lights
Red light - critical alarm (system off)
Yellow light - non-critical alarm (system running)
Green light - compressor on
Green flashing - compressor waiting on timer to start/stop
ROOM TEMP
DEFROST TYPE
VALVE TYPE
MOTOR TYPE
MOTOR STEP RATE
MAX VALVE STEPS
SUPERHEAT
MAX OPERATING PRES
REFRIGERANT
AUX TEMP MODE
AUX RELAY MODE
MIN COMP RUN TIME
MIN COMP OFF TIME
REFRIG FAN MODE
DEFROST MODE
DEFROSTS / DAY
1ST DEFROST DELAY
DEFROST FAN STATE
DEFROST TERM TEMP
DEFROST PARAMETER
DRAIN TIME
COMP RUN TIME
ELEC DEFROST MODE
FAN DELAY TEMP
MAX FAN DELAY TIME
PUMP DOWN TIME
MULTI AIR TEMP CTRL
MULTI EVAP COOL
MULTI EVAP DEFROST
MULTI EVAP SENSOR
HIGH TEMP ALARM OFFSET
HIGH TEMP ALARM DELAY
LOW TEMP ALARM OFFSET
LOW TEMP ALARM DELAY
DOOR ALARM DELAY
DIG IN 1 MODE
DIG IN 1 STATE
DIG IN 2 MODE
DIG IN 2 STATE
DIG IN 3 MODE
DIG IN 3 STATE
2ND ROOM TEMP
SUCT PRES OFFSET
SUCT TEMP OFFSET
AIR TEMP OFFSET
COIL TEMP OFFSET
AUX TEMP OFFSET
TEMP UNITS
AIR TEMP DIFF
EXTREME TEMP DIFF
Setpoints*
* The Setpoint paramenters shown
in BOLD (Valve Type, Room Temp
Setpoint and Defrost Mode) need to
be set by the user prior to start up.
The other Setpoint Parameters can
also be adjusted, however the
factory setpoints are generally
correct for most applications.
The Setpoint parameters shown in
ITALIC
are only displayed when an
EEV is used.
The Setpoint parameters shown in
BOLD ITALIC are displayed for
bonded controllers only.
ROOM TEMP
COIL TEMP
SYSTEM MODE
SUPERHEAT
SUCTION PRESSURE
SUCTION TEMP
SATURATION TEMP
VALVE % OPEN
AUX TEMP
COMPRESSOR RELAY
DEFROST RELAY
FAN RELAY
DIG 1 STATUS
DIG 2 STATUS
DIG 3 STATUS
IP OCTET 1
IP OCTET 2
IP OCTET 3
IP OCTET 4
SUBNET MASK OCTET 1
SUBNET MASK OCTET 2
SUBNET MASK OCTET 3
SUBNET MASK OCTET 4
FIRMWARE VERSION
Variables
for DIG IN Mode
DIG IN MODE = DISABLED
DIG IN MODE = 2ND (ROOM) TEMP
DIG IN MODE = DOOR SWITCH
DIG IN MODE = EXT ALARM
DIG IN MODE = SYSTEM OFF
DIG IN MODE = LIGHT SWITCH
DIG IN MODE = CAMERA SWITCH
KE2
Evaporator
Efficiency
TM
therm
solutions
ENTER
BACK
2
2
KE2 Evaporator Efficiency
A.1.20
January 2012